Digital Input and Output Functions
This function allows operators to select and set digital output ports. The system alarm function can program the
digital output ports as part of the alarm state change indication. The system alarm function can also program the
digital input ports as alarm trigger sources.
■
System-Wide Log View
The system supports the following system logs:
• Operator log
• Alarm log
• Video Loss log
• Switch log
In the WV-ASC970 Admin Console main screen select the
Tools, Logs, and System
links to view system wide user
logs and alarm logs.
Note:
• Each log file is saved based on pre-defined frequency in the "sys.ini" file. Also when the log size reaches
approximately 500 KB, the new file is created.
• The Switch log takes all switching information between monitor and camera.
■
Time Synchronization
The System Server can work as a stand-alone time server for i-PRO devices. Refer to WV-ASC970 Admin Console
User's Guide to setup time server.
■
Support WJ-HD616/WJ-HD716 as i-PRO Node
The System Server can handle the WJ-HD616/716 as an i-PRO node.
Users can see the analog camera video connected to WJ-HD616/716 on WJ-GXD400 monitor or WV-ASM970
Video Window. Refer to Appendix 3.
■
Support Camera Stream 1 or 2
In order to reduce the commands between the WJ-GXD400 and i-PRO cameras, The System Server can specify
the camera stream number 1 or 2, and image capture size of JPEG format for the WJ-GXD400 based on
WV-ASC970 Admin Console settings.