69
TimeDatePosition=1,1
CamTitlePosition=1,16
MonStatusPosition=1,15
GenStatusPosition=1,14
***{ Time-Date, Camera Title and Camera ID Controls }
***{ Code 2 takes effect only if source is MXOSD
}
***{ Format: <Control Name>=<control code>
}
***{ control code 0 - OFF
}
***{ control code 1 - ON
}
***{ control code 2 - By Operator
}
TimeDateControl=2
CamTitleControl=2
CamIDControl=2
***{ Time and Date display format
}
***{ Format: TimeDateFormat=<format> }
***{ format 0 - DD/MM/YYYY
}
***{ format 1 - MM/DD/YYYY
}
***{ format 2 - DD/Mmm/YYYY
}
***{ format 3 - YYYY/MM/DD
}
***{ format 4 - Mmm/DD/YYYY
}
***{ format 5 - DD/MM/'YY
}
***{ format 6 - MM/DD/'YY
}
***{ format 7 - DD/Mmm/'YY
}
***{ format 8 - 'YY/MM/DD
}
***{ format 9 - Mmm/DD/'YY
}
TimeDateFormat=1
***{ Time-Hour Display format
}
***{ Format: TimeHourFormat=<format> }
***{ format 0 - 12 Hour
}
***{ format 1 - 24 Hour
}
TimeHourFormat=0
UNIT section
Note:
• The unit ID should be unique number from 1 to 64 in the multiple domain system. In case of single domain sys
-
tem, this number should be "1".
[UNIT]
***{ The unit ID should be the same as the one defined in }
***{ the Global Admin database for this unit.
}
***{ For single-unit systems, use ID=1. (ID=0 is invalid)
}
ID=1
LOG section
This section sets the frequency with which log files are saved to hard disk. The defaults below have the
logs being copied every 10 minutes and stored for 7 days.