68
FRAMES section
Note:
• This section is only used for WV-SX850 cages definitions.
• Copy each value based on the existing WJ-MPU850/855's "sys.ini" file.
[FRAMES]
***{ MX Frame definition from Admin file
}
***{ MXSW has format <num_rows>,<num_cols>,<interface_num> }
***{ All others use <num_functions>,<interface_num>
}
MXSWFunction=8,4,0
MXCONTFunction=8,0
MXOSDFunction=2,0
MXDIOFunction=2,0
MXRMSFunction=0,0
PROCS section
This section tells the system which interface is to be used by certain process files.
[PROCS]
***{ Process Interface Assignments
}
***{ Format: <Process Name>=<interface_num>
}
***{ Set these three to the interface_num of the Ethernet keyboards: }
Keybp=1
Mxconts=1
Mxpfw=1
"1" means interface1 in [INTERFACES] section. WV-ASC970 Server has 3 software processes (listed
above) to communicate to a CU950. All processes should use same interface number. Factory default
setup is interface "1".
***{ Set Swcpu to the same interface_num for all unit CPUs:
}
Swcpu=0
"0" means interface0 in [INTERFACES] section. In case of Redundant System, Both CPUA and CPUB
must be assigned the same interface_num. Factory default setup is interface "0".
***{ Set UnitManager to the same interface_num for all system CPUs: }
UnitManager=0
***{ Set CSntp to the interface_num for EXTERNAL SNTP operation: }
CSntp=0
Not currently supported
***{ Set SSntp to the same interface_num for all system CPUs:
}
SSntp=0
Not currently supported
OSD section
All settings in this section are set to factory default, which provide the best monitor layout.
[OSD]
***{ Initial OSD display position
}
***{ Alarm text is placed on the General Status line.
}
***{ Format: <DisplayItemPosition>=<x-position>,<y-position> }