51
■
Alarm History Table
There are 1000 alarm records stored in chronological
order in 125 pages of table.
1. Select a desired monitor. (Refer to p. 39 Monitor
Selection.)
2. Press the ALM RECALL button. "AlarmHist" will
appear on the LCD, and the ALARM HISTORY
table will be displayed on the active monitor.
ALM:
Logical alarm number
STATE:
Indicates alarm state changes.
ARMED:
The system is armed for alarm
response.
ACTIVE:
Alarm has been triggered and activat-
ed assigned alarm response.
ACKED:
Alarm is acknowledged and an opera-
tor can control the alarm action.
RESET:
Activated alarm is reset, but the alarm
device is still active.
DISARMED:
The system is disarmed for alarm
response.
CLEARED:
Auto arming is not set in the admin
console.
DATE/TIME:
Date and time when alarm state
changes.
3. To display the next page, press the + button.
To display the previous page, press the – button.
MON AlarmHist CAM
0123 00512
ALARM HISTORY PG
ALM STATE DATE/TIME
1 DISARMED 01/01/01 12:00
1 ARMED 01/01/01 12:00
1 ACTIVE 01/01/01 12:00
1 ACKED 01/01/01 12:00
1 CLEARED 01/01/01 12:00
1 RESET 01/01/01 12:00
Note:
• To display the first page of table, press the + but
-
ton while holding down the SHIFT button.
• To display the last page of table, press the – button
while holding down the SHIFT button.
• Every time you press the button 0 while holding
down the MON (ESC) button, the monitor back-
ground will change between camera images and
black picture.
4. To exit the ALARM HISTORY table, press the
CLEAR button while holding down the MON (ESC)
button.
Note:
• This feature is available in only WJ-SX650 or
WJ-SX850 because of OSD limitation.