Alarm Export to other Domains
●
Alarm Export Function
This function allows a local alarm to export to other system domains.
●
Assign Alarm Export in WV-ASC970 Admin Console
In the WV-ASC970 Admin Components screen, select the Alarm Export tab. From there, you can edit an alarm to
be exported to multiple system domains (units). The alarm ID has the following format:
Unit (Domain) id (2) + Alarm id (1). E.g. 20001
In the above format, the domain ID has up to 2 digits and its range is from 1 … 64. The domain ID here is also
called alarm source domain, which means that the alarm originates from that domain.
●
Setup an Exported Alarm as Global Alarm source in WV-ASC970 Admin Console
After creating an alarm to be exported to a destination domain, an administrator must enter the alarm information
into the destination domain alarm database using its WV-ASC970 Admin Console.
In the WV-ASC970 Admin Console main menu, select Records from the Alarm command on the Components
menu. For alarm Source, select the source type Global Alarm and ID to 20001 (in the above case).
●
Reset Exported Alarm Simultaneously
In case that the Global Alarm Reset Synchronization check box in WV-ASC970 Admin Console is turned on, when
an operator reset the exported alarm in local unit, the exported alarms in other remote units are reset simultaneous-
ly.
■
Event Operation
The function allows administrators to program system events. The event function currently supports following oper-
ations:
• Camera spot
• Tour sequence
• Group Preset
• Group Sequence
• Arm and disarm alarm
• Up to 4 system modes
Note:
• The event function does not support the system modes during switchover in the redundant system.