Wiring
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
54
<Output waveform [control output (OSSD 1 / 2) ON]>
The receiver executes self-diagnosis of the output circuit when the device is in the light receiv-
ing state (ON state), and thus the output transistor turns OFF periodically. (Refer to the chart
below.)
When an OFF signal is fed back, the receiver determines that the output circuit is normal. If an
OFF signal is not fed back, the receiver determines that there is an output circuit or wiring error,
and the control output (OSSD 1 / 2) holds the OFF state.
CAUTION
Because the OFF signal of the device may cause the machine to malfunction, pay attention to the
input response time of the machine when connecting the machine to the device.
<Timing chart>
(Note 1)
80µs
100µs
50µs
80µs (Note 2)
80µs
50µs
50ms or less
Light received
Light blocked
Light reception
state
ON
OFF
Control output 1
(OSSD 1)
ON
OFF
Control output 2
(OSSD 2)
Notes: 1) Depends on main cycle: 2.6 to 8.9ms
2) Extended up to a maximum of 300μs when the load is a capacitance load.
Summary of Contents for WUME-SF4D-4
Page 2: ... Panasonic Industrial Devices SUNX Co Ltd 2017 2 MEMO ...
Page 126: ...Functions Panasonic Industrial Devices SUNX Co Ltd 2017 126 MEMO ...
Page 130: ...Maintenance Panasonic Industrial Devices SUNX Co Ltd 2017 130 MEMO ...
Page 140: ...Troubleshooting Panasonic Industrial Devices SUNX Co Ltd 2017 140 MEMO ...
Page 174: ... Panasonic Industrial Devices SUNX Co Ltd 2017 174 MEMO ...