Wiring
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
64
2-5-7 Wiring Configuration for Valid External Device Monitor Function
(Example of Control Category 4 Wiring)
Connect contact b of K1 and K2 to the external device monitor inputs as shown.
●
Using line synchronization setting and 8-core cable
<Using PNP output>
Load
K1 K2
Emitter
Receiver
K1
K2
+
24V DC
+20
-30
%
−
Gray cable
Gray cable
(with black line)
(Brown) +V
(Brown) +V
(Pale purple) Interlock setting input
(Pink) Test / Reset input
(Red) Auxiliary output
(Pale blue) Output polarity setting / Lockout release input
(Pale blue) Output polarity setting / Lockout release input
(Blue) 0V
(Blue) 0V
(Orange) Synchroni
(Pale purple) External device monitor input
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Orange) Synchroni
(Orange / Black) Synchronization -
(Orange / Black) Synchronization -
Interlock function
Invalid (auto reset)
External device monitor function Valid
Auxiliary output
Can be used
*Symbols
K1, K2: External device (forcible guide relay or magnetic conductor)