Functions
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
105
3-6 External Device Monitor Function (8-core cable, 12-core cable)
The external device monitor function is used to check if an external device (safety relay, con-
ductor) connected to the control output (OSSD 1 / 2) operates normally in accordance with the
control output (OSSD 1 / 2).
Contact “b” of the external device is monitored, and if an error is detected such as malfunction-
ing due to contact welding, the device is put in the lockout state and the control output (OSSD 1
/ 2) turns OFF.
The monitor time of contact “b” is 300ms. If 300ms is exceeded, the lockout state activates.
●
Enabling the external device monitor function
Connect the external device monitor input wire (pale purple) to the external safety relay that
is connected to the control output 1 (OSSD 1) wire (black) and the control output 2 (OSSD 2)
wire (white).
●
Disabling the external device monitor function
Connect the external device monitor input wire (pale purple) to the auxiliary output wire (red).
Set the auxiliary output to [negative logic of control output (OSSD 1 / 2)] (factory setting) [Set
using the communication module
SF4D-TM1
(option) and Configurator Light Curtain soft-
ware].
When the external device monitor function is invalid, external devices cannot be connected
to the auxiliary output.
<Reference>
You can invalid the external device monitor function using the communication module
SF4D-TM1
(option) and Configurator Light Curtain software. You can also change the allowed response time
within the range 100 to 600ms.
<Timing chart (Normal)>
ON
ON
OFF
OFF
300ms or less
300ms or less
50ms or less
(Note 1)
(Note 2)
(Note 2)
External device
monitor input
Control output
(OSSD 1 / 2)
Light received
Light blocked
Light received
state
<Timing chart (Error 1)>
ON
ON
OFF
OFF
300ms or less
(Note 1)
(Note 2)
External device
monitor input
Control output
(OSSD 1 / 2)
Light received
Light blocked
Light received
state
Lockout state
Summary of Contents for WUME-SF4D-4
Page 2: ... Panasonic Industrial Devices SUNX Co Ltd 2017 2 MEMO ...
Page 126: ...Functions Panasonic Industrial Devices SUNX Co Ltd 2017 126 MEMO ...
Page 130: ...Maintenance Panasonic Industrial Devices SUNX Co Ltd 2017 130 MEMO ...
Page 140: ...Troubleshooting Panasonic Industrial Devices SUNX Co Ltd 2017 140 MEMO ...
Page 174: ... Panasonic Industrial Devices SUNX Co Ltd 2017 174 MEMO ...