9
●
Setting the Termination and Controller
Unit Number
The Termination Switch and the Controller Unit Number
Switch are located on the rear of the System Controller.
When combined with the WJ-FS616 Video Multiplexer,
always keep these switches in the positions shown
below.
TERM.
MODE
ON
OFF
0
OFF
ON
●
Setting the Mode Selection Switch
The Mode Selection Switch, that selects the operation
mode of the System Controller, is located on the rear of
the System Controller.
When combined with the WJ-FS616 Video Multiplexer,
always keep these switches in the positions shown
below.
■
Connection with Alarm Sensors
Connect the sensor switches to the Alarm/Remote (ALARM/REMOTE) Control Connector on the rear of the Video Multiplexer
as shown in the example below.
37
19
20
1
SW2
SW1
SW16
GND
ALARM/REMOTE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
Function
Electronic Zoom
Sequence
Spot
Alarm/Remote Select Input
Sequence SW for Spot Output
Not Used
Alarm Recover Input
Alarm Output
Alarm 16
Alarm 14
Ground
Alarm 11
Alarm 9
Alarm 8
Alarm 6
Ground
Alarm 3
Alarm 1
Pin No.
Designation
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
Still Picture
VTR/Camera Select
Multiscreen Select
Multiscreen
Ground
Alarm & SW Output
Time Adjust Input
Alarm Reset Output
Ground
Alarm 15
Alarm 13
Alarm 12
Alarm 10
Ground
Alarm 7
Alarm 5
Alarm 4
Alarm 2
Pin No.