24
8
Execute Program Number 042 Press the Camera
Selection Button/Preset Position Button 4, 2 and 16
sequentially, the Menu as shown in Table 4-4 will be dis-
played.
Table 4-4
8
Connect the terminated Oscilloscope with 75
Ω
to the
Recording Output Connector on the Rear Panel.
8
Adjust VR18 so that the Border signal level becomes 700
± 14 mV as shown in Fig. 4-5.
8
Adjust VR36 so that the Burst signal level becomes 300 ±
14 mV as shown in Fig. 4-5.
8
Confirm that the Sync signal level becomes 300 ± 30 mV
as shown in Fig. 4-5.
Fig 4-5
8
Press the Reset Button.
8
Change the connection of the terminated Oscilloscope
with 75
Ω
to the Multiscreen Output Connector on the Rear
Panel.
8
Execute Program Number 044 Press the Camera
Selection Button/Preset Position Button 4, 4 and 16
sequentially, the Menu as shown in Table 4-5 will be dis-
played.
Table 4-5
8
Adjust VR20 so that the Border signal level becomes 700
± 14 mV as shown in Fig. 4-6.
SELF CHECK
042 H PHASE(R-2)
00-0F 0C
8
Adjust VR35 so that the Burst signal level becomes 300 ±
14 mV as shown in Fig. 4-6.
8
Confirm that the Sync signal level becomes 300 ± 30 mV
as shown in Fig. 4-6.
Fig 4-6
8
Press the Reset Button.
(7). Y Pedestal, Y Gain, Chroma Gain and Chroma
Phase Adjustment
Test Point:
Recording Output Connector
Rear Panel
Adjust:
VR25 (Y GAIN-0)
Switch Board
VR26 (Y GAIN-1)
Switch Board
VR27 (Y GAIN-2)
Switch Board
VR28 (Y GAIN-3)
Switch Board
VR29 (Y GAIN-4)
Switch Board
VR30 (Y GAIN-5)
Switch Board
VR31 (Y GAIN-6)
Switch Board
VR32 (Y GAIN-7)
Switch Board
VR33 (VBS Y GAIN)
Switch Board
VR22 (Y/C Y GAIN)
Switch Board
VR23 (Y/C C GAIN)
Switch Board
VR2 (C PHASE-0)
Switch Board
VR4 (C PHASE-1)
Switch Board
VR6 (C PHASE-2)
Switch Board
VR8 (C PHASE-3)
Switch Board
VR9 (C PHASE-4)
Switch Board
VR12 (C PHASE-5)
Switch Board
VR14 (C PHASE-6)
Switch Board
VR16 (C PHASE-7)
Switch Board
VR34 (C PHASE)
Switch Board
8
Supply the Ramp signal to the Camera Input Connectors
1, PLAY-IN Connector and S-Video Connector of the
Playback Input Connector on the Rear Panel.
Note : The supplied signals to the Camera Input
Connector 1 and S-Video Connector must be syn-
chronized.
8
Connect the terminated Oscilloscope with 75
Ω
to the
Recording Output Connector on the Rear Panel.
700
±
14 mV
300
±
30 mV
300
±
14 mV
SELF CHECK
044 H PHASE(M-2)
00-0F 0C
700
±
14 mV
300
±
30 mV
300
±
14 mV