8
CAMERA
IN
CAMERA
OUT
16
15
14
13
5
4
3
2
1
16
15
14
13
5
4
3
2
1
A B
T
A B
R
G
N
D
G
N
D
RS485
AUX
Alarm
Video Multiplexer WJ-FS616
■
Connection with the Camera Sites
Connect the Camera Site equipment to the Camera
Input Connectors (CAMERA IN 1-16) on the rear of the
Video Multiplexer.
Note: Make sure that the cable length between the
camera site and the WJ-FS616 Video Multiplexer is
less than 1 200 m (4 000 ft) when using RG-6/U (5C
- 2V) or equivalent cables.
Connect the Camera Site equipment to the RS485
Terminal on the rear of the Video Multiplexer, when
specified equipment is connected.
Note: If you use cables assembled from locally pro-
cured materials, it is important that only high quality,
data grade cable, suitable for RS-485 “2-wire twist-
ed pair shielded cable” is used.
Low grade cable will result in unstable operation of
the system.
■
Connection with the Monitors
Connect the Monitors to the Spot Output (SPOT OUT)
Connector and Multiscreen (MULTISCREEN) Connector
on the rear of the Video Multiplexer.
SPOT
MULTISCREEN
OUT
I N
VIDEO
S
–
VIDEO
Video Multiplexer
WJ-FS616
■
Connection with the WV-CU550A
System Controller
If the supplied 6-conductor cable assembly is used, sim-
ply plug one end of the cable into the DATA IN port of
the Video Multiplexer and the other end into DATA OUT
port on the System Controller.
If you use cables assembled from locally procured
materials, it is important that only high quality, data
grade cable, suitable for RS-485 “2-wire twisted pair
shielded cable” is used.
Low grade cable will result in unstable operation of the
system.
TERM.
OFF
IN
OUT
ON
DATA
IN
OUT
TERM
ON
OFF
DATA
0 1
2
3
45
6
7
8
9
CONTROLLER
UNIT NO.
1-8
Video Multiplexer
WJ-FS616
System Controller
WV-CU550A