32
Setup items
■
REC Type
Select "QUICK" or "ADVANCED" for validation of the recording settings.
QUICK:
The recording settings set on the setup menu (Quick) will be validated when recording.
ADVANCED:
The recording settings set on the setup menu (Advanced) will be validated when recording.
Note:
• When "QUICK" is selected, the setup menu (Quick) will be displayed by clicking the [Setup] tab. When
"ADVANCED" is selected, the setup menu (Advanced) will be displayed by clicking the [Setup] tab.
• When "QUICK" is selected, the following setup items of "Schedule" (Advanced) will not function. When it is nec-
essary to function the following items, select "ADVANCED".
* To perform the schedule recording, perform the settings for "Time Table" and "Program".
[Measurement] Button
It is possible to start calculation of maximum value of
recording rate/transmission rate (ips) that can be set for
"Live video", "Manual recording" and "Event recording"
by clicking this button.
Recording will stop for around 90 seconds due to the
calculation.
■
LIVE VIDEO
Set the transmission rate of live images from cameras.
The following are available for the transmission rate.
OFF/0.1 ips/0.2 ips/0.3 ips/0.5 ips/1 ips/2 ips/3 ips/
5 ips/10 ips/15 ips
■
Manual REC Operation
Perform the recording rate for manual recording.
The following are available for "Recording Rate".
OFF/0.1 ips/0.2 ips/0.3 ips/0.5 ips/1 ips/2 ips/3 ips/
5 ips/10 ips/15 ips
■
EVENT REC
Set the recording rate, recording duration and the event
action mode when an event (site alarm, terminal alarm,
command alarm) occurs.
The following are available for "Recording Rate".
OFF/0.1 ips/0.2 ips/0.3 ips/0.5 ips/1 ips/2 ips/3 ips/
5 ips/10 ips/15 ips
The following are available for "Time" (recording dura-
tion).
1 s - 10 s (in 1 second intervals)/20 s/30 s/1 min -
10 min (in 1 minute intervals)/20 min/30 min/40 min/
50 min/ 60 min
MANUAL:
Recording will be performed while alarm sig-
nals (camera site alarm, terminal alarm, command
alarm) are being supplied.
Submenu
Time Table
Setup items
Status
FTP SEND BY PERIODIC TIMER
Disabled
ERROR REPORT MAIL
Disabled
FTP Alarm Sending
Disabled
Alarm Message
Functions normally (Fixed to ON.)
Individual Alarm Notification
Disabled
Alarm Message
Disabled
Program
Special Days
Program 1 - 4
The settings performed on the setup menu
(Advanced) will not be validated.
The settings performed on the setup menu
(Quick) will be validated. *
Disabled
Summary of Contents for WJ-ND300 Administrator Console