214
17.5 To Remove RCCB
1. Disconnect lead wires (Black and White).
2. Remove screws to remove RCCB
17.6 To Remove Transformer and Electronic Controller Board
1. Disconnect and connector L1 & L2 (White) and G02
& G03 from the Electronic Controller Board.
2. Remove 2 screws to remove Reactor
3. Disconnect all connectors and
lead wire from the electronic controller
board. (Refer Indoor Unit Wiring
Connection Diagram)
4. Release 6 hooks from the electronic
controller board.
Electronic Controller Board
Reactor