18.8 To Remove Bottle Complete
18.9 To Remove Water Filter
3. Disconnect 2 pipe connection.
4. Remove 2 screws from bracket.
2. Remove Air Purge Valve.
1. Disconnect the connector CN_OLP1 from the
Electronic Controller and detached the lead
wire HT1-L3 (Red) and AC2-L3 (Black).
1. Set 2 valve for the
Water Filter Set to
“CLOSE”.
Retaining ring
2. Remove the retaining ring
then remove the Water Filter.
Filter