14.2.4.
Pump 2 Water Return Temperature Sensor Abnormality (H50)
Malfunction Decision Conditions:
During startup and operation of heating, the temperatures detected by the pump 2 water return temperature sensor are used to
determine sensor error.
Malfunction Caused:
1. Faulty connector connection.
2. Faulty sensor.
3. Faulty water tank unit PCB.
Abnormality Judgment:
Continue for 5 seconds.