17
1
Tank Unit To Indoor Unit /Heat Exchanger Unit Piping Installation
This Tank Unit is designed for combination with Panasonic
Air-to-Water Heatpump System (indoor unit and outdoor
unit). If another manufacturer’s indoor unit and outdoor unit
are being used in combination with Panasonic Tank Unit,
neither optimum operation nor reliability of the system is not
guaranteed. Thus warranty cannot be given in such case.
• Connect Tank Unit tube connector
A
(indicated with
“INDOOR UNIT (IN)”) to water outlet connector of indoor
unit.
• Connect Tank Unit tube connector
B
(indicated with
“INDOOR UNIT (OUT)”) to water inlet connector of indoor
unit.
• Do not install any valves between unit and water piping to
avoid accidental closure of water supply to the unit.
• Failure to connect the tubes appropriately might cause the
unit malfunction.
2
Cold Water Supply And Hot Water Supply Piping Installation
• In high water pressure or water supply is above 500kPa,
please install the regulator valve for water supply. If the
pressure higher than that, it might damage the Tank Unit.
• A Pressure Reducing Valve (purchased separately) with
below specification is strongly advised to be installed at the
cold water inlet
D
(indicate with “COLD WATER (IN)”) of
Tank Unit. Refer Typical piping installation section to locate
the Pressure Reducing Valve.
Recommended Pressure Reducing Valve specifications:
- Maximum outlet pressure: 0.3 Mpa (3 bars)
- Operating temperature range: Min. 1
q
C – Max. 70
q
C
- Sized to meet application and local code condition.
• Install an expansion vessel (purchase separately) on cold
urban water line if pressure reducing valve is used.
• Must connect a faucet to Tank Unit hot water outlet
C
(indicated with “HOT WATER (OUT)”) and urban water
supply, in order to supply water with appropriate temperature
for shower or tap usage. Failure to do so might cause
scalding.
• Failure to connect the tube appropriately might causing the
Tank Unit malfunction.
Summary of Contents for WH-TX30B9E8
Page 7: ...7 4 Location of Controls and Components 4 1 Tank Unit 4 1 1 Location of Control ...
Page 8: ...8 4 1 2 Main Components ...
Page 9: ...9 5 Dimensions ...
Page 10: ...10 6 Water Cycle Diagram ...
Page 11: ...11 7 Wiring Connection Diagram ...
Page 12: ...12 8 Electronic Circuit Diagram 8 1 Indoor Unit ...
Page 13: ...13 9 Printed Circuit Board 9 1 Tank Unit 9 1 1 Main Printed Circuit Board ...
Page 14: ...14 9 1 2 Surge Printed Circuit Board ...
Page 47: ...47 15 2 Heater Removal Procedures ...
Page 48: ...48 15 3 Main Printed Board Removal Procedures ...
Page 49: ...49 15 4 Control Board Removal Procedure ...
Page 50: ...50 15 5 Pressure Relief Valve Procedures ...
Page 51: ...51 15 6 Flow Switch Removal Procedures 15 7 Water Pump Removal Procedures ...
Page 52: ...52 16 Technical Data 16 1 Pump Characteristic 16 2 Water Tank Sensor Characteristic ...
Page 53: ...53 ...
Page 54: ...54 ...