44
Menus
For installer
Menu
Default Setting
Setting Options / Display
Water temp. for cooling ON
Compensation curve
Cooling ON
temperatures in
compensation curve
or direct input.
Water temp. for cooling ON Compensation curve
X axis: 20 °C, 30 °C
Y axis: 15 °C, 10 °C
Input the 4
temperature points
(2 on horizontal X
axis, 2 on vertical Y
axis)
•
If 2 zone system is selected, the 4 temperature points must also be input for Zone
2.
•
“Zone 1” and “Zone 2” will not appear on the display if only 1 zone system.
Water temp. for cooling ON Direct
10 °C
Set temperature for
Cooling ON
•
If 2 zone system is selected, temperature set point must input for Zone 2.
•
“Zone 1” and “Zone 2” will not appear on the display if only 1 zone system.
T for cooling ON
5 °C
Set T for cooling ON
* This setting will not
available to set when
pump
fl
owrate set to
Max. duty.
6.3
*
1,
*
2
Auto
Automatic switch from Heat to
Cool or Cool to Heat.
Outdoor temperatures for switching from Heat
to Cool or Cool to Heat.
Outdoor temp. for (Heat to Cool) /
Outdoor temp. for (Cool to Heat)
Outdoor temp. for (Heat to Cool)
15 °C
Set outdoor
temperature for
switching
from Heat to Cool.
*
1
The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service partners.
*
2
Only displayed when COOL mode is unlocked (This means when COOL mode is available).