28
Menus
For user
Menu
Default Setting
Setting Options / Display
2 System
check
2.1
Energy monitor
Present or historical chart of
energy consumption, generation
or COP.
Present
Month
Mode
Total consumption (1year)
0.0
1year 1 2 3 4 5 6 7 8 9 10 11 12
kWh
kWh
Approx.
CMth
Jan, 2022:
0.0
Select and retrieve
Historical chart
Select and retrieve
•
COP= Coef
fi
cient of Performance.
•
For historical chart, the period is selected from 1 day/1 week/1year.
•
Energy consumption (kWh) of heating, *
1,
*
2
cooling, tank and total may be
retrieved.
•
The total power consumption is an estimated value based on AC 230 V and
may differ from value measured by precise equipment.
2.2
System information
Shows all system information in
each area.
Actual system information of 11 items:
Inlet / Outlet / Zone 1 / Zone 2 / Tank /
Buffer tank / Solar / Pool / COMP
frequency / Pump
fl
owrate / Water pressure
Select and retrieve
2.3
Error history
•
Refer to Troubleshooting for
error codes.
•
The most recent error code is
displayed at the top.
Select and retrieve
2.4
Compressor
Shows the compressor
performance.
Select and retrieve
2.5
Heater
Total hours of ON time for
Room heater/Tank heater.
Select and retrieve
*
1
The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service partners.
*
2
Only displayed when COOL mode is unlocked (This means when COOL mode is available).
Summary of Contents for WH-SDC12K6E5
Page 54: ...Memo...