13
4.1.3 To adjust initial settings
• The system may not work properly if set wrongly. Please consult
Dealer
Select menus and determine settings according to the system available in the
household. It is recommended that all alterations of settings are done by an
authorised dealer or specialist.
• After initial installation, you may manually adjust the settings.
The initial setting remains active until the user changes it.
• The remote control can be used for multiple installations.
• Ensure the operation LED is OFF before setting.
an authorised dealer.
1
Press
and
simultaneously and hold for
5 seconds until the display shows SETTING STATUS.
2
Press
or
to select the menu.
3
Press
to enter the menu.
4
Press
or
to select YES/NO, or other options.
YES:
to enable the menu
NO:
to disable the menu
5
Press
to confirm.
Remote Control
Display
Operation LED
Menu (1 ~ 17)
Default
Setting
Setting
1
Room Thermostat Connection
To select whether or not to connect to the optional room
thermostat.
2
Backup Heater Selection
To reduce the heater power if unnecessary.
*Options of kW vary depending on the model.
9 kW
*3 kW / 6 kW /
9 kW
3
Water System Freeze Prevention
To activate or deactivate the water freeze prevention when the
system is OFF.
4
Tank Connection
To select whether or not to connect to the optional water tank unit.
Note: If NO is selected, menus 5 to 15 are skipped.
5
Solar Priority
To select the use of solar panel for heating up the water tank.
6
Heating Priority
To select the room heating as priority during HEAT + TANK mode.
Note: If YES is selected, menus 7 and 8 are skipped for HEAT +
TANK mode.
7
Heating Operation Interval
To set the interval for HEAT mode during HEAT + TANK mode.
Note: If YES is selected in menu 6, this menu is skipped.
3 hours
0.5 hours ~
10 hours
8
Tank Heat-up Interval
To set the interval for the water tank during HEAT + TANK mode.
Note: If YES is selected in menu 6, this menu is skipped.
30 minutes
5 minutes ~
1 hour 35 minutes
Display
NO
YES
NO
NO
YES
NO
NO
YES
NO
NO
YES
NO
YES
YES
NO
Summary of Contents for WH-MHF09G3E8
Page 32: ...32 10 1 2 Solar Printed Circuit Board Optional ...
Page 33: ...33 10 2 Refrigerant System 10 2 1 Main Printed Circuit Board ...
Page 34: ...34 10 2 1 1 Noise Filter Printed Circuit Board ...
Page 47: ...47 Heat Mode Operation Time Chart ...
Page 49: ...49 ...
Page 50: ...50 ...
Page 56: ...56 ...
Page 57: ...57 ...
Page 58: ...58 ...
Page 127: ...127 17 3 To Remove The Cabinet Rear Plate 17 4 To Remove Pressure Gauge 17 5 To Remove RCCB ...
Page 138: ...138 19 2 Water System 44 46 17 16 4 34 42 18 43 3 33 9 1 45 45 47 2 35 48 36 19 ...