16.5.23 IPM Overheating (F22)
Malfunction Decision Conditions:
During operation of heating, when temperature 95°C is detected by the outdoor IPM temperature sensor.
Malfunction Caused:
1 Faulty outdoor unit fan motor.
2 Faulty outdoor unit PCB (main).
Abnormality Judgment:
Continue 3 times in 30 minutes.