![Panasonic VL-V901 Installation And Operating Instructions Manual Download Page 54](http://html1.mh-extra.com/html/panasonic/vl-v901/vl-v901_installation-and-operating-instructions-manual_3989310054.webp)
Parameter
Description and available settings
Default
Terminal 1–4 Name Code
Determines the name for terminal 1–4.
[1]: TERMINAL #
[2]: RECEPTION
[3]: GATE
[4]: CONTROL ROOM
[5]: RESTAURANT
[6]: HALL
[7]: POOL
[8]: SECURITY OFFICE
[9]: ENTRANCE
[10]: GYM
[11]: GUEST ROOM
[12]: KID’S ROOM
[13]: PARKING
[14]: TERRACE
[15]: LIFT LOBBY
1
(TERMINAL #)
Terminal 1–4 Reception Code
Determines whether terminal 1–4 is a reception
terminal or a normal terminal (i.e., cannot be used as a
reception terminal).
[0]: NORMAL TERMINAL
[1]: RECEPTION TERMINAL
0
(NORMAL
TERMINAL)
Emergency Terminal Extension
Number
Tells the system the extension number for the
emergency terminal.
(24 digits max.)
—
Emergency Terminal Emergency
Mode
Determines whether the emergency terminal can talk
to residents during an emergency call (emergency talk
mode) or if the emergency terminal receives an
announcement only (emergency notice mode).
[0]: EMERGENCY TALK
[1]: EMERGENCY NOTICE
0
(EMERGENCY
TALK)
Lobby Station 1–3 — Room settings
Parameter
Description and available settings
Default
Room No.
Determines the room number.
(1–99999; 0 is displayed when the room is not
configured)
—
Resident Name
Determines the resident name for the corresponding
room number.
(20 characters max., uppercase letters only)
—
Lobby Station 1–3 — General settings
Parameter
Description and available settings
Default
Door Key Open Time
Determines the amount of time the door stays open. If
set to 0 SEC, the door cannot be opened.
(1–20 SEC, or 0 to disable)
5 SEC
Door Key Out Signal
Determines whether the signal sent to the electric lock
is a closed signal (i.e., the signal is normally open) or
an open signal (i.e., the signal is normally closed).
[0]: CLOSE
[1]: OPEN
0
(CLOSE)
54
5. Programming