![Panasonic VL-V901 Installation And Operating Instructions Manual Download Page 19](http://html1.mh-extra.com/html/panasonic/vl-v901/vl-v901_installation-and-operating-instructions-manual_3989310019.webp)
USB
USB 2.0, standard-B connector
SD card
4–64 GB SDHC / SDXC memory card is supported
Whole system capacity
R
Lobby station (VL-V900/VL-V901):
–
Fully expanded system (page 4):
up to 3
–
Fully expanded system using 3 extension boxes (page 5):
up to18 (6
lobby stations per extension box with a maximum of 3 extension boxes
connected to 1 control box)
–
Fully expanded system for enhanced features version 2 or later
(page 6, 92):
up to 54
*1 Consult your certified Panasonic dealer for more information about
expanding the system.
R
Main monitor (VL-MW251, VL-MVN511, VL-MV26, VL-MWD272,
VL-MWD273, VL-MV71, VL-MV72):
up to 560 (The maximum, for each branch, 7 distribution boxes, 1 repeater,
and 140 main monitors can be connected.)
Fully expanded system for enhanced features version 2 or later
(page 6, 92):
up to 2240
(The maximum, for each branch, 10 distribution boxes, 1 repeater, and 140
main monitors can be connected.)
R
Lift controller (VL-V702): up to 3 branches, totally up to 15 lift controllers
R
Guard stations: up to 4 (in case of connecting to the PBX system)
Fully expanded system for enhanced features version 2 or later
(page 6, 92):
up to 16 (in case of connecting to the PBX system)
Distribution Box (VL-V701)
Power source
Power supply unit (VL-PS240: 220 – 240 V AC, 0.2 A, 50 / 60 Hz)
24 V DC, 0.6 A
Power consumption
Standby: Approx. 1.2 W
Operating: Approx. 2.0 W
Dimensions (mm)
(height
´
width
´
depth)
Approx. 210
´
108.5
´
52.5 (excluding protruding sections)
Mass (weight)
Approx. 400 g
Operating environment
Ambient temperature: approx. -10 °C to +50 °C
Ambient temperature for power supply unit: approx. 0 °C to +50 °C
Relative humidity: up to 90% (non-condensing)
Indoor installation only
Installation method
Wall mount or attach to DIN rail
External material
ABS (flame retardant ABS resin)
Connectivity
To main monitor
Number of connectable stations: 20
Wire: 1 pair PE insulation, thickness of one conductor is from 0.65 – 1.2 mm
Distance: up to 200 m (in case of 1.2 mm thickness)
To control box
Number of connectable stations: 1
Wire: 2 pair PE insulation, thickness of one conductor is from 0.65 – 1.2 mm
Distance: up to 200 m (in case of 1.2 mm thickness)
To distribution box
Number of connectable stations: 1
Wire: 2 pair PE insulation, thickness of one conductor is from 0.65 – 1.2 mm
Distance: up to 200 m (in case of 1.2 mm thickness)