![Panasonic VL-V901 Installation And Operating Instructions Manual Download Page 48](http://html1.mh-extra.com/html/panasonic/vl-v901/vl-v901_installation-and-operating-instructions-manual_3989310048.webp)
Connection Check
Allows you to confirm the control box’s connection to the main monitors and lift controllers.
5.2.4 Using the version 1 setup tool to edit data
1
Start the setup tool.
2
In the
[Prepare the data]
section, click
[Check Files]
.
R
The paths of each configuration file are displayed in the
[Load and edit the data]
section.
3
In the
[Load and edit the data]
section, click
[Load / Edit ...]
next to a configuration file that you want to edit.
R
The files’s details are displayed.
4
For [Room settings] for lobby stations 1–3
a.
Click
[Edit ...]
to open the configuration file.
R
Use a third-party text editor or spreadsheet program to open the configuration file.
b.
Change the values in the appropriate columns, and then save the file.
c.
In the setup tool, click
[Reload]
.
R
The content of the configuration is reloaded and displayed.
d.
Click
[Close]
.
For all other settings
a.
Select the desired setting.
b.
Enter the desired value in the
[Edit Data]
section.
R
Acceptable values are displayed in a pop-up when you mouse-over the text field.
c.
Click
[Apply / Save]
to save the settings to the configuration file.
d.
Click
[Close]
.
5
Repeat from step 3 for each configuration file that you want to edit.
R
Files that are ready to be uploaded are indicated by
[OK]
displayed in the right side of the
[Load and edit the
data]
section.
6
In the
[Upload the data to device]
section, select the devices that you want to upload the data to and then click
[Upload]
.
Note:
R
See 5.2.13 List of PC programming parameters (Page 53) for information about each parameter.
48