![Panasonic VL-V700 Installation And Operating Instructions Manual Download Page 61](http://html.mh-extra.com/html/panasonic/vl-v700/vl-v700_installation-and-operating-instructions-manual_269796061.webp)
Parameter
Description and available settings
Default
SET WIDE/ZOOM
WIDE/ZOOM SETTINGS
Determines whether camera images are displayed in
wide mode or in zoom mode when monitoring begins.
[00]: WIDE
[01]: ZOOM
00
(
WIDE
)
ZOOM POSITION
Determines the camera zoom position.
[01]: UPPER LEFT
[02]: UPPER SIDE
[03]: UPPER RIGHT
[04]: LEFT
[05]: CENTRE
[06]: RIGHT
[07]: LOWER LEFT
[08]: LOWER SIDE
[09]: LOWER RIGHT
05
(
CENTRE
)
SET POWER FREQ.
Tells the system what frequency of power is supplied
to the lobby station.
[00]: 50 HZ
[01]: 60 HZ
00
(
50 HZ
)
SET CAMERA SIGNAL
Tells the system what signal format is used by the
external camera.
[00]: PAL
[01]: NTSC
00
(
PAL
)
SET TIME&DATE
Determines the system’s time and date settings.
1/JAN/2015
00:00
SET TIME OUT
MONITOR TIME OUT
Determines the amount of time that passes when
watching camera images before the standby screen is
displayed.
[00]: 180 SEC
[01]: 90 SEC
[02]: 60 SEC
[03]: 30 SEC
00
(
180 SEC
)
TALK TIME OUT
Determines the amount of time that passes when
talking before the standby screen is displayed.
[00]: 90 SEC
[01]: 60 SEC
[02]: 30 SEC
[03]: 180 SEC
[04]: 300 SEC
00
(
90 SEC
)
SET LIFT
SIGNAL MODE TO LIFT
Determines the signalling method used by the lift
controller to communicate with the lift. Select the signal
type according to the specifications of the lift.
[00]: RELAY
[01]: BINARY
00
(
RELAY
)
61
5. Programming