Lift controller wiring example (relay signalling)
Control Box (1)
USB
NP: Non-polarised
DC IN
NP
POWER SUPPLY UNIT
Lift Controller (up to 15; up to 5 lift controllers per lift x 3 lifts)
DC IN
NP
POWER SUPPLY UNIT
DIP SW : 1=ON
1
0 F
19 F
Lift 1
DC IN
NP
POWER SUPPLY UNIT
DIP SW : 5=ON
5
80 F
99 F
NP
. .
Lift 1
DC IN
NP
POWER SUPPLY UNIT
DIP SW : 1=ON
1
0 F
19 F
Lift 2
DC IN
NP
POWER SUPPLY UNIT
DIP SW : 5=ON
5
80 F
99 F
NP
. .
Lift 2
NP
NP
DC IN
NP
POWER SUPPLY UNIT
DIP SW : 1=ON
1
0 F
19 F
Lift 3
DC IN
NP
POWER SUPPLY UNIT
DIP SW : 5=ON
5
80 F
99 F
NP
. .
Lift 3
NP
V900/
V901/
V703
34