![Panasonic VL-V700 Installation And Operating Instructions Manual Download Page 56](http://html.mh-extra.com/html/panasonic/vl-v700/vl-v700_installation-and-operating-instructions-manual_269796056.webp)
Parameter
Description and available settings
Default
Zoom Position
Determines the camera zoom position.
[1]: UPPER LEFT
[2]: UPPER SIDE
[3]: UPPER RIGHT
[4]: LEFT
[5]: CENTRE
[6]: RIGHT
[7]: LOWER LEFT
[8]: LOWER SIDE
[9]: LOWER RIGHT
5
(CENTRE)
Power Frequency
Tells the system what frequency of power is supplied
to the lobby station.
[0]: 50 HZ
[1]: 60 HZ
0
(50 HZ)
Access Code
Determines the access code that allows you to use
lobby stations to configure the system.
(6 digits)
123456
*1
For systems that support enhanced features version 3 or later (page 92)
When relay signaling is used by the lift controller, settings for stopping on multiple floors for all lifts (up to 5 separate
floor settings) are supported. (The same floor settings are used for all lifts.)
Control Box — Room settings
Parameter
Description and available settings
Default
Room No.
Determines the room number of the main monitor
connected to the corresponding control box port,
distribution box number, and distribution box port.
(1–99999; 0 is displayed when the room is not
configured)
0
Floor No.
Determines the floor number setting of the
corresponding room number.
(0–99; 0 is the ground floor)
R
When determining the multi floor number
setting (up to 5 separate floor settings):
Enter values such as the following in order to
configure multiple stopping floors.
Stopping floor entry example for 1F, 2F, 3F, 4F,
and 5F:
1F2F3F4F5F
0
Lift access permission (Lift 1–3)
Determines which lifts can be used by visitors to
each lobby station.
0
(No lifts can be
used)
Note:
R
When binary signaling is used by the lift controller, only stopping on the first configured floor is allowed even
if multiple stopping floors are configured.
*2
For systems that support enhanced features version 2 or later (page 92)
Gate call settings can be configured for each lobby station and camera connected to each control box.
Control Box — General settings
56
5. Programming