11
Introduction and Installation
Wiring schematic diagram
Note:
L
This door opener wiring schematic diagram is only an example. Refer to the wiring
instructions provided with your door opener and PBX for details.
L
Refer to the technical data on page 30 when connecting to a door opener.
Power cable/wire type and distance
L
Power cable (between the monitor station and the AC adaptor):
Type:
Ф
1.2 Fire alarm cable 16 AWG
Distance: Maximum 30 m (about 98 feet)
L
Wire (between the monitor station and the door station):
Type: General cable CAT-3 24 AWG
Distance: Maximum 100 m (about 328 feet)
Loop resistance: 18.4
Ω
or lower
L
Wire (between the monitor station and PBX):
Type: General cable CAT-3 24 AWG
Distance: Maximum 100 m (about 328 feet)
D1 D2
Door station
Monitor station
AC adaptor
Power cable
(Non polar)
(Non polar)
(Non polar)
D1
D2
P1
P2
S1
S2
PBX
(Example: KX-TDA50)
Door opener
Terminal box
(4-conductor wiring)
Power cord