TH-65PF10UK
9
4 Specifications
Power Source
120 V AC, 50/60Hz
Power Consumption
Power on
790 W
Stand-by condition
Save OFF 0.6 W, Save ON 0.4 W
Power off condition
0.1W
Plasma Display panel
Drive method: AC type 65-inch, 16:9 aspect ratio
Screen size
56.5
”
(1,434 mm) (W)
×
31.8
”
(807 mm) (H)
×
65
”
(1,646 mm) (diagonal)
(No. of pixels)
2,073,600 (1,920 (W)
×
1,080 (H)) [5,760
×
1,080 dots]
Operating condition
Temperature
32
°
F - 104
°
F (0
°
C - 40
°
C)
Humidity
20 % - 80 %
Applicable signals
Scanning format
525 (480) / 60i 60p, 625 (575) / 50i 50p, 750 (720) / 60p 50p, 1125 (1080) /
60i 60p 50i 50p 24p 25p 30p 24sF, 1250 (1080) / 50i
PC signals
VGA, SVGA, XGA, SXGA,
UXGA ..... (compressed)
Horizontal scanning frequency 15 - 110 kHz
Vertical scanning frequency 48 - 120 Hz
Connection terminals
HDMI A-B
TYPE A Connector
×
2
COMPONENT / RGB IN
Y/G (BNC)
with sync 1.0 Vp-p (75-ohm)
P
B
/B (BNC), P
R
/R (BNC)
0.7 Vp-p (75-ohm)
AUDIO IN (RCA PIN JACK
×
2)
0.5 Vrms (high impedance)
PC IN
(HIGH-DENSITY MINI D-SUB 15PIN)
Y or G with sync 1.0 Vp-p (75-ohm)
Y or G without sync 0.7 Vp-p (75-ohm)
B/P
B
/C
B
: 0.7 Vp-p (75-ohm)
R/P
R
/C
R
: 0.7 Vp-p (75-ohm)
HD/VD: 1.0 - 5.0 Vp-p (high impedance)
AUDIO IN (M3 JACK)
0.5 Vrms
SERIAL
EXTERNAL CONTROL TERMINAL (D-SUB 9PIN)
RS-232C COMPATIBLE
SPEAKERS
8-ohm, 20 W [10 W + 10 W] (10 % THD)
Accessories Supplied
Remote Control Transmitter
EUR7636070R
Batteries
AA Size
×
2
Fixing bands
TMME203
×
2
Dimensions (W
×
H
×
D)
61.2
”
(1,554 mm)
×
36.4
”
(925 mm)
×
3.9
”
(99 mm) (excluding handle portion)
Mass (weight)
main unit only
approx. 158.7 lbs
with speakers
approx. 172.0 lbs
Note:
• Design and specifications are subject to change without notice. Mass and dimensions shown are approximate.
Summary of Contents for Viera TH-65PF10UK
Page 7: ...TH 65PF10UK 7 3 2 Applicable signals ...
Page 8: ...TH 65PF10UK 8 ...
Page 10: ...TH 65PF10UK 10 5 Operating Instructions ...
Page 15: ...TH 65PF10UK 15 6 2 IIC mode structure following items value is sample data ...
Page 33: ...TH 65PF10UK 33 9 1 4 Adjustment Volume Location 9 1 5 Test Point Location ...
Page 35: ...TH 65PF10UK 35 ...
Page 37: ...TH 65PF10UK 37 ...
Page 58: ...TH 65PF10UK 58 11 2 Wiring 2 The lead wiring is dressed as shown in figure ...
Page 59: ...TH 65PF10UK 59 12 Schematic Diagram 12 1 Schematic Diagram Notes ...
Page 147: ...TH 65PF10UK 147 14 1 4 Flat cable relation 32 31 29 28 29 28 30 33 37 2 ...
Page 148: ...TH 65PF10UK 148 14 1 5 Accessories 21 1 3 24 27 ...
Page 150: ...TH 65PF10UK 150 14 2 Electrical Replacement Parts List 14 2 1 Replacement Parts List Notes ...