TH-65PF10UK
16
7 Troubleshooting Guide
7.1.
Self Check
7.1.1.
Display Indication
1. Self-check is used to automatically check the bus line controlled circuit of the Plasma display.
2. To get into the Self-check mode, press the
volume down
button on the customer controls at the bottom of the set, at the
same time pressing the
OFF-TIMER
button on the remote control, and the screen will show.
If the IIC ports have been checked and found to be incorrect.
Or not located then “ - - ” will appear in place of “ OK ”.
“ 01 ” in the line of the “ PTCT ” means the number of blinks of the Power LED is 1. (Refer to 7.1.2)
“ H09 ” in the line of the “ PTCT ” is the error code.
To exit Self Check mode, switch off the main power.
Note:
The line of the “ PTCT ” displays when you get into the Self-check mode for the first time only after the Power LED blinks.
Summary of Contents for Viera TH-65PF10UK
Page 7: ...TH 65PF10UK 7 3 2 Applicable signals ...
Page 8: ...TH 65PF10UK 8 ...
Page 10: ...TH 65PF10UK 10 5 Operating Instructions ...
Page 15: ...TH 65PF10UK 15 6 2 IIC mode structure following items value is sample data ...
Page 33: ...TH 65PF10UK 33 9 1 4 Adjustment Volume Location 9 1 5 Test Point Location ...
Page 35: ...TH 65PF10UK 35 ...
Page 37: ...TH 65PF10UK 37 ...
Page 58: ...TH 65PF10UK 58 11 2 Wiring 2 The lead wiring is dressed as shown in figure ...
Page 59: ...TH 65PF10UK 59 12 Schematic Diagram 12 1 Schematic Diagram Notes ...
Page 147: ...TH 65PF10UK 147 14 1 4 Flat cable relation 32 31 29 28 29 28 30 33 37 2 ...
Page 148: ...TH 65PF10UK 148 14 1 5 Accessories 21 1 3 24 27 ...
Page 150: ...TH 65PF10UK 150 14 2 Electrical Replacement Parts List 14 2 1 Replacement Parts List Notes ...