background image

INSTALLATION  

GENERAL 

Please read this guide completely before 

installation or use of the modules. 

OPERATING CONDITIONS 

Panasonic recommends that modules be 

operated within the following Operating 

Conditions. An installation location with 

conditions beyond the Operating Condi-

tions or with other Special Conditions 

(see below) should be avoided.  Operat-

ing Conditions of Panasonic modules are 

as follows: 

1) The modules should be operated only 

in terrestrial applications. No space or 

other Special Conditions. 

2) The operating temperature must be 

within –40°C to 85°C. 

3) The relative humidity should be within 

45% to 95%. 

4) The wind pressure load of the installa-

tion site should be less than 2,400N/m

2

 

(50PSF). 

UNPACKING AND HANDLING 

 

Do not hit the back sheet of a mod-

ule by the connector when unpack-

ing and handling. 

 

Please do not expose the connector 

the rain water and dust . 

 

To avoid the damage of the back 

sheet

 

by the connector, fix the ca-

bles to the frame with tape after 

unpacking. (refer Figure 4) 

 

Do not handle modules by their 

cables or junction box. Handle them 

by the frame with both hands in any 

situation. 

 

The anti-reflection glass of a module 

is easy to be soiled, when it is 

grasped by hand or hand gloves. So 

it is recommended to hold card-

board or frames when carrying or 

installing the solar module. When 

cables and connectors touch the 

surface of the glass, it may soil the 

surface too. It is also recommended 

to avoid contact of cables and con-

nectors with surface of the glass. (If 

the glass surface becomes dirty, see 

section of "anti-reflection glass sur-

face cleaning".)  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 4. Fixing of cables 
and connectors

 

Summary of Contents for VBHNxxxSJ25 series

Page 1: ...sted in this manual are trademarks or registered trademarks of respective companies General Installation Manual VBHNxxxSJ25 series VBHNxxxSJ45 series VBHNxxxSJ47 series Photovoltaic Module HITTM Thank...

Page 2: ...g higher current and as mod ules are connected in series produc ing higher voltages The shock hazard increases as mod ules with nominal open circuit volt age Voc in excess of 45 V and or modules rated...

Page 3: ...ermining voltage ratings con ductor capacities fuse sizes and size of controls connected to the module output 3 The current output for the modules shown in the Specifications is meas ured at Standard...

Page 4: ...e positions of the holes are all symmetrical against the center of the module Front side Figure 1 1 Module dimensions VBHNxxxSJ25 Dimension in mm Back side Side Figure 1 1 a Optional Mounting Range A...

Page 5: ...otection rating A 15 Factory Installed Bypass Diode pcs 4 Length x Width x Height mm 1463 x 1053 x 35 Weight kg 18 Table 1 2 Model Specifications Silicone hetero junction Mono crystalline Silicon amor...

Page 6: ...Vsys V 1000 Maximum over current protection rating A 15 Factory Installed Bypass Diode pcs 4 Length x Width x Height mm 1590 x 1053 x 35 Weight kg 19 Table 1 3 Model Specifications Silicone hetero ju...

Page 7: ...w through the shaded area This may cause undesirable heating to occur The use of a diode to bypass the shaded area can minimize both heating and array current reduction All modules are equipped with f...

Page 8: ...ING AND HANDLING Do not hit the back sheet of a mod ule by the connector when unpack ing and handling Please do not expose the connector the rain water and dust To avoid the damage of the back sheet b...

Page 9: ...that could result in deterioration or corrosion Clearance 100mm between the roof surface and module frame is re quired to allow cooling air to circu late around the back of the module This also allows...

Page 10: ...olar Module Metal clamp B 2 places Metal clamp A 2 places Mounting Structure Rail 38mm 38mm 35mm 11mm Figure 5 2 Module Installation VBHNxxxSJ40 VBHNxxxSJ47 Solar Module Metal clamp B 2 places Metal c...

Page 11: ...erature conditions to ensure com pliance with maximum system volt age limitations Do not connect module in parallel without using connection devices that connect to appropriate FUSE for each series st...

Page 12: ...ass to clean any part of the module The performance of a solar module may be reduced Please be very careful since the guarantee will not cover damages caused by detergents When cleaning the PV module...

Page 13: ...86 6295 Panasonic Eco Solutions Sales Thailand Co Ltd Tel 66 0 2 231 3683 Fax 66 0 2 231 3899 Panasonic Eco Solutions Hong Kong Co Tel 852 2466 1708 Fax 852 2466 1473 Panasonic Eco Solutions Sales Tai...