background image

12 

MAINTENANCE 

 

In order to maintain the optimum 

output of the module, quality and 

safety, please conduct periodic in-

spection or cleaning. 

 

It is also recommended to inspect 

the electrical and mechanical con-

nections annually. 

 

If you need electrical or mechanical 

inspection or maintenance, it is rec-

ommended to have a licensed au-

thorized professional carry out the 

inspection or maintenance to avoid 

the hazards of electric shock or inju-

ry. 

ANTI-REFLECTION GLASS SUR-

FACE CLEANING 

 

Light dirt that does not shield light 

completely does not significantly 

degrade power generation perfor-

mance, but if the module surface 

becomes dirty, it may reduce output 

power. malfunction or hotspot may 

occur. 

 

It is recommended to clean the sur-

face of the module with water and 

a soft cloth or sponge. 

 

When cleaning with neutral glass 

detergent or weak alkaline glass 

detergent, it is recommended to 

start with smallest area and from 

the edge of solar module in order to 

check no damage occurs to the 

glass. 

 

After that, clean surface of glass 

with wet and clean cloth. 

 

Recommended detergent: "Glass 

Magiclean"1) or "Windex® Origi-

nal"2) 

1) Glass Magiclean is a trademark of 

Kao Corporation. 

2) Windex® is a trademark of SC 

Johnson & Son,Inc. 

 

It is recommended to read carefully 

the manuals of detergent and un-

derstand notes on usage and first-

aid treatment. 

 

To remove persistent dirt, the mod-

ule can be washed with a micro-

fiber cloth and ethanol. 

 

Never use abrasive detergent, 

strong alkaline detergent, strong 

acid detergent or a detergent which 

forms a protective layer on the sur-

face of the glass to clean any part of 

the module. The performance of a 

solar module may be reduced. 

Please be very careful since the 

guarantee will not cover damages 

caused by detergents. 

 

When cleaning the PV module, 

please do not put detergent on 

junction box or connector. If deter-

gents and chemical substances ad-

here, junction box and connector 

may be deteriorated or damaged. 

 

DISPOSAL OF OLD EQUIPMENT 

This symbol on the products, 

and/or accompanying docu-

ments means

 

that used elec-

trical and electronic products 

must not be mixed with gen-

eral household waste.  

For proper treatment, recovery and recy-

cling of old products, please take them

 

to applicable collection points in accord-

ance with your national legislation. 

For more information about collection 

and recycling, please contact your local 

municipality. 

Penalties may be applicable for incorrect 

disposal of this waste, in accordance with 

national legislation. 

DISCLAIMER OF LIABILITY 

Panasonic does not assume responsibility 

and expressly disclaims liability for loss, 

damage, or expense arising out of, or in 

any way connected with installation, 

operation, use, or maintenance by using 

this manual.   

Panasonic assumes no responsibility for 

any infringement of patents or other 

rights of third parties, which may result 

from use of modules.  

No license is granted by implication or 

under any patent or patent rights. The 

information in this manual is believed to 

be reliable, but does not constitute an 

expressed and/or implied guarantee.  

As part of our policy of continuous im-

provement, Panasonic reserves the right 

to make changes to the product, specifi-

cations, or manual at any time without 

prior notice. 

The return of any modules will not be 

accepted by Panasonic unless prior writ-

ten authorization has been given by 

Panasonic. 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for VBHNxxxSJ25 series

Page 1: ...sted in this manual are trademarks or registered trademarks of respective companies General Installation Manual VBHNxxxSJ25 series VBHNxxxSJ45 series VBHNxxxSJ47 series Photovoltaic Module HITTM Thank...

Page 2: ...g higher current and as mod ules are connected in series produc ing higher voltages The shock hazard increases as mod ules with nominal open circuit volt age Voc in excess of 45 V and or modules rated...

Page 3: ...ermining voltage ratings con ductor capacities fuse sizes and size of controls connected to the module output 3 The current output for the modules shown in the Specifications is meas ured at Standard...

Page 4: ...e positions of the holes are all symmetrical against the center of the module Front side Figure 1 1 Module dimensions VBHNxxxSJ25 Dimension in mm Back side Side Figure 1 1 a Optional Mounting Range A...

Page 5: ...otection rating A 15 Factory Installed Bypass Diode pcs 4 Length x Width x Height mm 1463 x 1053 x 35 Weight kg 18 Table 1 2 Model Specifications Silicone hetero junction Mono crystalline Silicon amor...

Page 6: ...Vsys V 1000 Maximum over current protection rating A 15 Factory Installed Bypass Diode pcs 4 Length x Width x Height mm 1590 x 1053 x 35 Weight kg 19 Table 1 3 Model Specifications Silicone hetero ju...

Page 7: ...w through the shaded area This may cause undesirable heating to occur The use of a diode to bypass the shaded area can minimize both heating and array current reduction All modules are equipped with f...

Page 8: ...ING AND HANDLING Do not hit the back sheet of a mod ule by the connector when unpack ing and handling Please do not expose the connector the rain water and dust To avoid the damage of the back sheet b...

Page 9: ...that could result in deterioration or corrosion Clearance 100mm between the roof surface and module frame is re quired to allow cooling air to circu late around the back of the module This also allows...

Page 10: ...olar Module Metal clamp B 2 places Metal clamp A 2 places Mounting Structure Rail 38mm 38mm 35mm 11mm Figure 5 2 Module Installation VBHNxxxSJ40 VBHNxxxSJ47 Solar Module Metal clamp B 2 places Metal c...

Page 11: ...erature conditions to ensure com pliance with maximum system volt age limitations Do not connect module in parallel without using connection devices that connect to appropriate FUSE for each series st...

Page 12: ...ass to clean any part of the module The performance of a solar module may be reduced Please be very careful since the guarantee will not cover damages caused by detergents When cleaning the PV module...

Page 13: ...86 6295 Panasonic Eco Solutions Sales Thailand Co Ltd Tel 66 0 2 231 3683 Fax 66 0 2 231 3899 Panasonic Eco Solutions Hong Kong Co Tel 852 2466 1708 Fax 852 2466 1473 Panasonic Eco Solutions Sales Tai...

Reviews: