background image

MODULE SPECIFICATIONS 

 

Module specifications are shown in 

Table 1-1, 1-2, 1-3 and Figure 1-1, 1-

1-a, 1-1-b, 1-2, 1-3. (Electrical specifi-

cations, mechanical specifications, 

module dimensions) 

1) 

Rated electrical characteristics are 

within the range of +10% to -5% of 

the values measured at Standard 

Test Conditions (STC). Irradiance of 

1000W/m

2

, 25

±

2

 cell tempera-

ture, AM1.5 and solar spectral irradi-

ance according to IEC 60904-3. 

2) 

Under normal conditions, a module 

may experience conditions that 

produce more current and/or volt-

age than reported at standard com-

ponent test conditions. Accordingly, 

the values of Isc and Voc should be 

multiplied by a factor of 1.25 when 

determining voltage ratings, con-

ductor capacities, fuse sizes, and 

size of controls connected to the 

module output. 

3) 

The current output for the modules 

shown in the Specifications is meas-

ured at Standard Test Conditions. 

These conditions may not be fre-

quently observed in actual practice. 

Table 1-1. Model Specifications

 

Silicone hetero-junction*: Mono-crystalline Silicon/amorphous silicon hetero-junction

 

Model  

 

VBHN240SJ25

 

VBHN245SJ25

 

Maximum Power (Pmax)

 

+

10/-0 %

 

W

 

240

 

245

 

Open Circuit Voltage (Voc)

 

±

10 %

 

V

 

52.4

 

53.0

 

Short Circuit Voltage (Isc)

 

90 %

 

A

 

5.85

 

5.86

 

Maximum Power Voltage (Vpm) 

 

V

 

43.6

 

44.3

 

Maximum Power Current (Ipm) 

 

A

 

5.51

 

5.54

 

Cell Number in  Series 

 

pcs

 

72

 

Cell Type  

 

Silicon hetero-junction*

 

Maximum System Voltage (Vsys) 

 

V

 

1000

 

Maximum over-current protection rating

 

A

 

15

 

Factory Installed Bypass Diode

 

pcs

 

43

 

Length x Width x Height

 

mm

 

1580 x 798 x 35

 

Weight

 

kg

 

15

 

Summary of Contents for VBHNxxxSJ25 series

Page 1: ...sted in this manual are trademarks or registered trademarks of respective companies General Installation Manual VBHNxxxSJ25 series VBHNxxxSJ45 series VBHNxxxSJ47 series Photovoltaic Module HITTM Thank...

Page 2: ...g higher current and as mod ules are connected in series produc ing higher voltages The shock hazard increases as mod ules with nominal open circuit volt age Voc in excess of 45 V and or modules rated...

Page 3: ...ermining voltage ratings con ductor capacities fuse sizes and size of controls connected to the module output 3 The current output for the modules shown in the Specifications is meas ured at Standard...

Page 4: ...e positions of the holes are all symmetrical against the center of the module Front side Figure 1 1 Module dimensions VBHNxxxSJ25 Dimension in mm Back side Side Figure 1 1 a Optional Mounting Range A...

Page 5: ...otection rating A 15 Factory Installed Bypass Diode pcs 4 Length x Width x Height mm 1463 x 1053 x 35 Weight kg 18 Table 1 2 Model Specifications Silicone hetero junction Mono crystalline Silicon amor...

Page 6: ...Vsys V 1000 Maximum over current protection rating A 15 Factory Installed Bypass Diode pcs 4 Length x Width x Height mm 1590 x 1053 x 35 Weight kg 19 Table 1 3 Model Specifications Silicone hetero ju...

Page 7: ...w through the shaded area This may cause undesirable heating to occur The use of a diode to bypass the shaded area can minimize both heating and array current reduction All modules are equipped with f...

Page 8: ...ING AND HANDLING Do not hit the back sheet of a mod ule by the connector when unpack ing and handling Please do not expose the connector the rain water and dust To avoid the damage of the back sheet b...

Page 9: ...that could result in deterioration or corrosion Clearance 100mm between the roof surface and module frame is re quired to allow cooling air to circu late around the back of the module This also allows...

Page 10: ...olar Module Metal clamp B 2 places Metal clamp A 2 places Mounting Structure Rail 38mm 38mm 35mm 11mm Figure 5 2 Module Installation VBHNxxxSJ40 VBHNxxxSJ47 Solar Module Metal clamp B 2 places Metal c...

Page 11: ...erature conditions to ensure com pliance with maximum system volt age limitations Do not connect module in parallel without using connection devices that connect to appropriate FUSE for each series st...

Page 12: ...ass to clean any part of the module The performance of a solar module may be reduced Please be very careful since the guarantee will not cover damages caused by detergents When cleaning the PV module...

Page 13: ...86 6295 Panasonic Eco Solutions Sales Thailand Co Ltd Tel 66 0 2 231 3683 Fax 66 0 2 231 3899 Panasonic Eco Solutions Hong Kong Co Tel 852 2466 1708 Fax 852 2466 1473 Panasonic Eco Solutions Sales Tai...