6
3) Place the Personal computer system(Display monitor,Keyboard,mouse and PC with installed UD-794
Control software on top panel of UD-794.
4) Remove the cover of the PC. Verify that the boards in the PC expansion bus are properly inserted and
seated in their slots.
5) Connect the National Instruments DIO I/F cable and gnd-cable from the UD-794 case to the slot in the PC
expansion board. See below figure
6) Connect the two 50-pin ribbon cable assemblies to the 50-pin headers H1 and H2 on the digital I/O board.
Insure correct Pin 1 orientation with Pin 1 of the ribbon cable assemblies (Brown is pin 1).