8.4.3.
V-Amp, V-Linear and V-Pos
Adjustment
1. Adjust Vertical amplitude for 2.3 ± 0.1 division of a scale by
V-Amp control.
2. Confirm Vertical Linear as to the balance of circle, if need
adjust V-Linear control.
3. Confirm Vertical Center, if it is not correct, adjust
Monoscope pattern for center of the screen by V-Pos
control.
8.4.4.
Parabola and Trapezoid
Adjustment
1. Receive NTSC cross hatch pattern.
2. Adjust the vertical line to straight line by Parabola control.
3. Adjust the vertical line to straight line of both side Vertical
line by Trapezoid control.
8.5.
525p Deflection Adjustment /
Confirmation
8.5.1.
V / H-Deflection confirmation
1. Receive 525p signal.
2. Confirm V / H-Deflection is normal.
8.5.2.
H-Pos confirmation / Adjustment
1. Receive 525p signal.
2. Confirm H-Pos and if need, adjust H-Pos.
8.6.
625p Deflection Adjustment /
Confirmation
8.6.1.
V / H-Deflection confirmation
1. Receive 625p signal.
2. Confirm V / H-Deflection is normal
8.6.2.
H-Pos confirmation / Adjustment
1. Receive 625p signal.
2. Confirm H-Pos and if need, adjust H-Pos.
25
TX-47P800HQ / TX-47P800HZ
Summary of Contents for TX-47P800HQ TX-47P800HZ
Page 15: ...15 TX 47P800HQ TX 47P800HZ ...
Page 16: ...6 3 Option Descrition 16 TX 47P800HQ TX 47P800HZ ...
Page 17: ...17 TX 47P800HQ TX 47P800HZ ...
Page 18: ...18 TX 47P800HQ TX 47P800HZ ...
Page 41: ...Fine Convergence Control Chart 41 TX 47P800HQ TX 47P800HZ ...
Page 42: ...42 TX 47P800HQ TX 47P800HZ ...
Page 44: ...11 4 Location of Lead Wiring 4 44 TX 47P800HQ TX 47P800HZ ...
Page 48: ...11 6 Location of Lead Wiring 6 11 7 Location of Lead Wiring 7 48 TX 47P800HQ TX 47P800HZ ...
Page 49: ...11 8 Location of Lead Wiring 8 11 9 Location of Lead Wiring 9 49 TX 47P800HQ TX 47P800HZ ...
Page 50: ...50 TX 47P800HQ TX 47P800HZ ...