106
English
[Password]
The keyboard for setting the password is displayed. After
entering the password, select [Ok]; the confirmation
screen is displayed. Enter the password again and
select [Ok]; the password is determined.
●
Entering characters (see page 154)
[Save]
Saves the settings above in the display unit.
Note
●
The default password is “1111”.
●
The security password is used when performing
[Shipping] and [Network settings] - [Reset].
●
Change the password at a regular interval to make it
hard to be guessed.
●
For how to initialize the security password, consult
your dealer.
■
[Shipping]
Restores the data of this unit to the factory default state.
For more detail of the settings, see “Shipping condition”.
(see page 158)
Note
●
When [Security password] - [Security password] is set
to [On], it is necessary to input the password before
performing [Shipping].
Control settings
Sets each item of the function which enables to control
multiple displays at the same time, or individually.
[Control settings] - submenu screen
Control settings
Serial response(ID all)
Off
Display ID
Controller ID function
Off
Serial ID function
Off
Serial response (Normal)
On
0
■
[Display ID]
Set ID number when controlling the Display with
[Controller ID function] and [Serial ID function].
0 to 100
(Standard value: 0)
■
[Controller ID function]
Enables/disables the [Controller ID function].
[Off]:
Disables the [Controller ID function]. (Can be
operated as normal remote control.)
[On]:
Enables the [Controller ID function]. Effective on
switching to [On].
Note
●
To use the [Controller ID function], setting ID numbers
both for the remote control and for the display unit is
required.
For ID number setting for the remote control, see
page 153.
●
About how to reset the settings to defaults, refer to
“Initialization”. (see page 159)
■
[Serial ID function]
Set to control external control with the PC connected to
SERIAL terminal according to the Display’s ID number.
[Off]:
Disables external control by the ID.
[On]:
Enables the external control by the ID.
■
[Serial response (Normal)]
Sets whether to send the response command to normal
commands without ID.
[Off]:
Does not respond. (Including the inquiry
command)
[On]:
Responds.
■
[Serial response(ID all)]
Set whether to respond to the command or not, when
serial command of ID number “0” is received.
[Off]:
Does not respond.
[On]:
Responds.
Information timing
Set up the informing manner for no signal or
temperature rising.
RS-232C controls:
Warning or error message sent from the display
automatically.
LAN controls:
Acquire the warning or error message from the
display.
[Information timing] - submenu screen
Information timing
No signal warning
No signal warning timing
Temperature warning
No signal error
No signal error timing
On
5min
On
10min
On
■
[No signal warning]
When set to [On], the display sends out the no signal
warning.
■
[No signal warning timing]
Set up the detecting time for no signal warning.
(Range: 01 ‒ 60, Interval: 1 minute)
■
[No signal error]
When set to [On], the display sends out the no signal
error.