TH-103PF10UK/EK
Option Menu for G PF10D series
GPH10D chassis series have special function and operation setting facility called Option Menu. This Option Menu is use
ful for special function required customers. This should be set at the installation stage.
Option menus
default setting
Contents
W eekly Com m and Timer
---
O ff-tim er Sets W eekly Com mand Timer. Enable/Disable.
O nscreen display
On
Enable/Disable to display input mode indication after power on and no signal
indication.
Initial INPUT
O ff
Sets the initial input mode when the pow er is turned on. Allow input mode selec
tion while pow er is on.
Initial VOL level
O ff
Sets the initial volum e level when the power is turned on. Allow Volume control
while power is on.
M aximum VOL Level
O ff
Sets the m aximum volum e to desired level. Volume cannot exceed this level.
INPUT lock
O ff
Fixes the input mode to AV, Com ponent/RG B or PC. Can not change input
mode by input selection key
Button lock
O ff
Enable/Disable bottom operation buttons (Input, Menu, Enter and/or volum e up/
down)
Rem ocon User Level
O ff
Remote key invalidation.
Off: Valid key is all key o f remote.
User1: Valid key are only Stand-by (ON/OFF), Input, Direct input, Status, Sur
round, Sound mute On/Off, and volum e adjustment.
User2: Valid key is only Stand-by (ON/OFF).
User3: All keys are null and void
Advanced PIP
O ff
Off: Sets normal two screen display mode.
On: Sets Advanced PIP mode.
Off-tim er function
Enable
O ff-tim er operation Enable/Disable.
Initial Power Mode
Normal
Sets the power mode o f the unit for when the power recovers from failure or
after plugging o ff and in again.
ID select
0
Set ID num ber from 0 to 100.
Remote ID
O ff
Remote ID function On/Off.
(While the Remote ID on, standard remote function can not control the unit.)
Serial ID
O ff
Serial ID function O n/O ff
Display size
O ff
Adjusts the im age display size on screen.
On: Sets the image display size approxim ately 95% o f the norm al im age dis
play.
Studio W/B
O ff
Set warm mode color tem perature to 3,200 Kelvin.
Studio Gain
O ff
Sharpens the contrast for a better view when a part o f the image is too light to
see
Slot power
O ff
Sets the slot power mode while the power is turned on.
Allow O ptional Terminal Board insert Slots while power is on.
Power On Screen Delay
O ff
You can set the power-on delay time o f the displays to reduce the power load,
when you press ( [ ) / | to turn on the m ultiple displays that are set together, for
example, on MULTI DISPLAY system.
Set each display'fs setting individually.
V. Installation
O ff
V. Installation function O n/O ff (Not used)
Rotate
O ff
The image rotates 180 degrees (up-down)
Serial Slot Select
Slot1
Selects the slot which com m unicates serial.
Note:
The setting o f an external com m and can be set only from the fixed serial
term inal.
Note:
W hen both main unit buttons and remote control are disabled due to the "Button lock", "Remocon User level" or "Rem ote ID"
adjustments, set all the values "Off" so that all the buttons are enabled again.
Press the "Volume down" button on main unit together with "R" button on the remote control and hold for more than 5 seconds.
The "SHIPPING" menu is displayed and the lock is released when it disappears.
17
Summary of Contents for TH-103PF10EK
Page 6: ...TH 103PF10UK EK 3 Service Navigation 3 1 Service Hint 6 ...
Page 15: ...TH 103PF10UK EK 5 2 IIC mode structure following items value is sample data 15 ...
Page 16: ...TH 103PF10UK EK 5 3 Option Setting 16 ...
Page 57: ...TH 103PF10UK EK Structure of replacement Plasma Panel Spare Parts 57 ...
Page 61: ...TH 103PF10UK EK 8 1 4 Adjustment Volume Location 8 1 5 Test Point Location 61 ...
Page 83: ...TH 103PF10UK EK 9 15 D Board 2 of 2 Block Diagram CABLE TSXL568 D31 CD1 TSXL569 C20 CD2 81 ...
Page 105: ...TH 103PF10UK EK 10 11 Lead Wiring 3 101 ...
Page 108: ...TH 103PF10UK EK 10 14 Lead Wiring 6 104 ...
Page 110: ...TH 103PF10UK EK 10 16 Lead Wiring 8 106 ...
Page 111: ...TH 103PF10UK EK 10 17 Lead Wiring 9 107 ...
Page 113: ...Model No TH 103PF10UK EK Exploded View ...
Page 114: ...Model No TH 103PF10UK EK Cabinet part location ...
Page 115: ...Model No TH 103PF10UK EK Side Power part location ...
Page 116: ...Model No TH 103PF10UK EK Fan part location Fan C ...
Page 117: ...Model No TH 103PF10UK EK Rear cover location ...
Page 118: ...Model No TH 103PF10UK EK Cable relation ...
Page 119: ...Model No TH 103PF10UK EK Board and Fuse ...
Page 120: ...Model No TH 103PF10UK EK Packing summary 1 49 201 18 AC power cord TH 103PF10UK TH 103PF1OEK ...
Page 121: ...Model No TH 103PF10UK EK Packing summary 2 41 ...
Page 122: ...Model No TH 103PF10UK EK Packing summary 3 ...
Page 123: ...Model No TH 103PF10UK EK Packing summary 4 ...
Page 124: ...Model No TH 103PF10UK EK Packing summary 5 ...
Page 125: ...Model No TH 103PF10UK EK Packing summary 6 ...