TH-103PF10UK/EK
1
Safety Precautions
1.1.
General Guidelines
1. W hen conducting repairs and servicing, do not attempt to modify the equipment, its parts or its materials.
2. W hen wiring units (with cables, flexible cables or lead wires) are supplied as repair parts and only one wire or some of the
wires have been broken or disconnected, do not attempt to repair or re-wire the units. Replace the entire wiring unit instead.
3. W hen conducting repairs and servicing, do not twist the Faston connectors but plug them straight in or unplug them straight
out.
4. W hen servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
5. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
6. After servicing, make the following leakage current checks to prevent the custom er from being exposed to shock hazards.
1.2.
Leakage Current Hot Check (See
Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use
an isolation transform er for this check.
2. Connect a 1.5kohm, 10 watts resistor, in parallel with a
0.15|iF capacitors, between each exposed metallic part
on the set and a good earth ground such as a water pipe,
as shown in Figure 1.
3. Use an AC voltmeter, with 1000 ohm s/volt or more sensi
tivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the volt
age at each point.
5. Reverse the AC plug in the AC outlet and repeat each of
the above measurements.
6. The potential at any point should not exceed 0.75 volts
RMS. A leakage current tester (Simpson Model 229 or
equivalent) may be used to make the hot checks, leakage
current must not exceed 1/2 milliamp. In case a measure
ment is outside of the limits specified, there is a possibility
of a shock hazard, and the equipm ent should be repaired
and rechecked before it is returned to the customer.
1.1.1.
Leakage Current Cold Check
1. Unplug the AC cord and connect a jum per between the
two prongs on the plug.
2. Measure the resistance value, with an ohmmeter,
between the jumpered AC plug and each exposed metal
lic cabinet part on the equipm ent such as screwheads,
connectors, control shafts, etc. W hen the exposed metal
lic part has a return path to the chassis, the reading
should be between 1Mohm and 5.2Mohm.
W hen the exposed metal does not have a return path to
the chassis, the reading must beO O .
1.1
Figure 1
3
Summary of Contents for TH-103PF10EK
Page 6: ...TH 103PF10UK EK 3 Service Navigation 3 1 Service Hint 6 ...
Page 15: ...TH 103PF10UK EK 5 2 IIC mode structure following items value is sample data 15 ...
Page 16: ...TH 103PF10UK EK 5 3 Option Setting 16 ...
Page 57: ...TH 103PF10UK EK Structure of replacement Plasma Panel Spare Parts 57 ...
Page 61: ...TH 103PF10UK EK 8 1 4 Adjustment Volume Location 8 1 5 Test Point Location 61 ...
Page 83: ...TH 103PF10UK EK 9 15 D Board 2 of 2 Block Diagram CABLE TSXL568 D31 CD1 TSXL569 C20 CD2 81 ...
Page 105: ...TH 103PF10UK EK 10 11 Lead Wiring 3 101 ...
Page 108: ...TH 103PF10UK EK 10 14 Lead Wiring 6 104 ...
Page 110: ...TH 103PF10UK EK 10 16 Lead Wiring 8 106 ...
Page 111: ...TH 103PF10UK EK 10 17 Lead Wiring 9 107 ...
Page 113: ...Model No TH 103PF10UK EK Exploded View ...
Page 114: ...Model No TH 103PF10UK EK Cabinet part location ...
Page 115: ...Model No TH 103PF10UK EK Side Power part location ...
Page 116: ...Model No TH 103PF10UK EK Fan part location Fan C ...
Page 117: ...Model No TH 103PF10UK EK Rear cover location ...
Page 118: ...Model No TH 103PF10UK EK Cable relation ...
Page 119: ...Model No TH 103PF10UK EK Board and Fuse ...
Page 120: ...Model No TH 103PF10UK EK Packing summary 1 49 201 18 AC power cord TH 103PF10UK TH 103PF1OEK ...
Page 121: ...Model No TH 103PF10UK EK Packing summary 2 41 ...
Page 122: ...Model No TH 103PF10UK EK Packing summary 3 ...
Page 123: ...Model No TH 103PF10UK EK Packing summary 4 ...
Page 124: ...Model No TH 103PF10UK EK Packing summary 5 ...
Page 125: ...Model No TH 103PF10UK EK Packing summary 6 ...