background image

12

Specifications

Ceiling 

(Type T3)

Model Name

S-3650PT3E

S-6071PT3E

S-1014PT3E

Power source

 (Europe)

220 - 230 - 240 V

~ 

50 Hz

Power source 

(Oceania)

230 - 240 V

 50 Hz

Cooling capacity

kW

3.5

4.0

5.0

6.0

6.8

9.5

12.1

13.4

BTU/h

11,900

13,600

17,100

20,500

23,200

32,400

41,300

45,700

Sensible

kW

3.0

3.3

3.8

4.7

5.2

7.3

8.8

9.5

Latent

kW

0.5

0.7

1.2

1.3

1.6

2.2

3.3

3.9

Heating capacity

kW

4.0

4.7

5.6

7.0

8.0

11.2

14.0

16.0

BTU/h

13,600

16,000

19,100

23,900

27,300

38,200

47,800

54,600

Cooling electric 

power input *

kW

0.035

0.040

0.040

0.050

0.055

0.080

0.110

0.120

Heating electric 

power input *

kW

0.035

0.040

0.040

0.050

0.055

0.080

0.110

0.120

Sound 

pressure 

level **

High

dB(A)

36

37

37

38

39

42

46

47

Medium

dB(A)

32

33

33

34

35

37

40

41

Low

dB(A)

28

28

28

29

30

34

35

36

Sound 

power 

level **

High

dB(A)

54

55

55

56

57

60

64

65

Medium

dB(A)

50

51

51

52

53

55

58

59

Low

dB(A)

46

46

46

47

48

52

53

54

Unit dimensions

(H×W×D) 

mm

235×960×690 235×960×690 235×960×690 235×1,275×690 235×1,275×690 235×1,590×690 235×1,590×690 235×1,590×690

Net weight 

kg

26

26

26

34

34

40

40

40

Operation condition temperature range

• Cooling mode : 18°C~32°C DB    • Heating mode : 16°C~30°C DB

*  In the case of nanoe™ X ‘‘OFF’’

**  Fan speed display on the remote controller

 High  : 

 (CZ-RTC4), 

 (CZ-RTC5B, CZ-RTC6*)

  Medium : 

 (CZ-RTC4), 

 (CZ-RTC5B, CZ-RTC6*)

 Low  : 

 (CZ-RTC4), 

 (CZ-RTC5B, CZ-RTC6*)

Indoor unit

01_330091_EN.indb   12

2021/1/13   9:49:11

Summary of Contents for T3 Series

Page 1: ...structions thoroughly and keep them for future reference Panasonic Corporation 1006 Kadoma Kadoma City Osaka Japan WEB ACXF55 28660 EN Ceiling Type T3 Model No INDOOR UNIT Ceiling Type T3 S 3650PT3E S...

Page 2: ...e as described in these Operating Instructions Confirm to authorized dealer or specialist on usage of specified refrigerant type Using of refrigerant other than the specified type may cause product da...

Page 3: ...oles must be incorporated in the fixed wiring in accordance with the wiring rules To prevent possible hazards from insulation failure the unit must be grounded WARNING Do not use modified cord joint c...

Page 4: ...appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision o...

Page 5: ...t recovery and recycling of old products and used batteries please take them to applicable collection points in accordance with your national legislation and the Directives 2002 96 EC and 2006 66 EC B...

Page 6: ...r intake Air intake Operation Adjusting Airflow Direction Refer to the Operating Instructions attached to the Remote Controller The flap display on the remote controller differs from the actual flap a...

Page 7: ...peration automatically Operation settings prior to power failure will be used WARNING z z For safety be sure to turn the air conditioner off and disconnect the power before cleaning Otherwise electric...

Page 8: ...opagations of mold and bacteria When purchased the nanoe X function is designed to automatically operate If you wish to set to OFF refer to the operating instructions for the remote controller adaptab...

Page 9: ...Fan rotation makes operation smooth The fan may rotate to dry the heat exchanger depending on the setting Airflow direction Airflow direction changes while operating Airflow direction cannot be set Ai...

Page 10: ...indows are open The air filter is clogged See Maintenance P 7 Too many heat sources in the room in cooling mode Use minimum heat sources and in a short time Too many people in the room in cooling mode...

Page 11: ...ZH2E8 PZ2 1 phase U 71PZ2E5 U 100PZ2E5 U 125PZ2E5 U 140PZ2E5 3 phase U 100PZ2E8 U 125PZ2E8 U 140PZ2E8 Outdoor unit type 36 50 60 PZH3 1 phase U 36PZH3E5 U 50PZH3E5 U 60PZH3E5 3 phase PZ3 1 phase U 36P...

Page 12: ...r input kW 0 035 0 040 0 040 0 050 0 055 0 080 0 110 0 120 Sound pressure level High dB A 36 37 37 38 39 42 46 47 Medium dB A 32 33 33 34 35 37 40 41 Low dB A 28 28 28 29 30 34 35 36 Sound power level...

Page 13: ...ing Heating dB A 65 67 69 69 70 70 71 71 Unit dimensions H W D mm 996 940 340 1 416 940 340 1 416 940 340 1 416 940 340 Net weight kg 68 99 99 99 Europe Model Name U 71PZH2E8 U 100PZH2E8 U 125PZH2E8 U...

Page 14: ...10 C 43 C DB Heating mode 15 C 24 C DB Europe Model Name U 100PZ2E8 U 125PZ2E8 U 140PZ2E8 Power source 380 400 415 V 3N 50 Hz Cooling capacity kW 10 0 12 5 14 0 BTU h 34 100 42 700 47 800 Heating capa...

Page 15: ...69 69 70 70 71 71 Unit dimensions H W D mm 996 940 340 1 416 940 340 1 416 940 340 1 416 940 340 Net weight kg 65 98 98 98 Europe Model Name U 71PZH3E8 U 100PZH3E8 U 125PZH3E8 U 140PZH3E8 Power sourc...

Page 16: ...0PZ3E8 U 125PZ3E8 U 140PZ3E8 Power source 220 230 240 V 50 Hz 380 400 415 V 3N 50 Hz Cooling capacity kW 10 0 12 5 14 0 10 0 12 5 14 0 BTU h 34 100 42 700 47 800 34 100 42 700 47 800 Heating capacity...

Page 17: ...ic com Panasonic Corporation 2020 2021 WEB ACXF55 28660 EN DC1020 10121 Authorised representative in EU Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg Germany 0...