3

If the refrigerant comes in contact

with a flame, it produces a toxic

gas.
For safety, be sure to turn the 

air conditioner off and also to 

disconnect the power before 

cleaning or servicing.
Pull off the power plug from  

a receptacle, or switch off  

the breaker, or switch off 

the power disconnecting mean to 

isolate the air conditioner from the 

main power supply in case of 

emergency.
Dispose of according to national 

and/or local legislation.

This product must not be modified 

or disassembled under any 

circumstances.

Modified or disassembled unit 

may cause fire, electric shock or 

injury.
Do not clean inside the indoor and 

outdoor units by users. Engage 

authorized dealer or specialist for 

cleaning.
In case of malfunction of this 

appliance, do not repair by yourself. 

Contact the sales dealer or service 

dealer for a repair and disposal.

Provide a power outlet to be used 

exclusively for each unit, and a

power supply disconnect, Earth 

Leakage Circuit Breaker (ELCB)

or Residual Current Device (RCD) 

for overcurrent protection should

be provided in the exclusive line.
Provide a power outlet 

exclusively for each unit, and full 

disconnection means having a 

contact separation in all poles 

must be incorporated in the fixed 

wiring in accordance with the 

wiring rules.
To prevent possible hazards  

from insulation failure, the 

unit must be grounded.

WARNING

Do not use modified 

 

cord, joint cord, 

extension cord or 

unspecified cord to prevent 

overheating and fire. 

The appliance shall be stored 

in a room without continuously 

operating ignition sources (for 

example: open flames, an 

operating gas appliance or an 

operating electric heater).
Be aware that refrigerants may 

not contain an odour.
An unventilated area where 

the appliance using flammable 

refrigerants is installed shall be 

so constructed that should any 

refrigerant leak, it will not stagnate 

so as to create a fire or explosion 

hazard. 
The appliance shall be stored 

in a well-ventilated area where 

the room size corresponds to 

the room area as specified for 

operation.
After the unit is installed, never 

fail to ask the installer for the floor 

space of the room where the unit 

is installed and the refrigerant 

charge amount.
In case the unit or the room 

divider is changed, never fail to 

consult the sales dealer or service 

dealer.
Do not use means to accelerate 

the defrosting process or to clean, 

other than those recommended 

by the manufacturer.
Do not pierce or burn.
In cases that require mechanical 

ventilation, ventilation openings 

shall be kept clear of obstruction.

01_330091_EN.indb   3

2021/1/13   9:49:03

Summary of Contents for T3 Series

Page 1: ...structions thoroughly and keep them for future reference Panasonic Corporation 1006 Kadoma Kadoma City Osaka Japan WEB ACXF55 28660 EN Ceiling Type T3 Model No INDOOR UNIT Ceiling Type T3 S 3650PT3E S...

Page 2: ...e as described in these Operating Instructions Confirm to authorized dealer or specialist on usage of specified refrigerant type Using of refrigerant other than the specified type may cause product da...

Page 3: ...oles must be incorporated in the fixed wiring in accordance with the wiring rules To prevent possible hazards from insulation failure the unit must be grounded WARNING Do not use modified cord joint c...

Page 4: ...appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision o...

Page 5: ...t recovery and recycling of old products and used batteries please take them to applicable collection points in accordance with your national legislation and the Directives 2002 96 EC and 2006 66 EC B...

Page 6: ...r intake Air intake Operation Adjusting Airflow Direction Refer to the Operating Instructions attached to the Remote Controller The flap display on the remote controller differs from the actual flap a...

Page 7: ...peration automatically Operation settings prior to power failure will be used WARNING z z For safety be sure to turn the air conditioner off and disconnect the power before cleaning Otherwise electric...

Page 8: ...opagations of mold and bacteria When purchased the nanoe X function is designed to automatically operate If you wish to set to OFF refer to the operating instructions for the remote controller adaptab...

Page 9: ...Fan rotation makes operation smooth The fan may rotate to dry the heat exchanger depending on the setting Airflow direction Airflow direction changes while operating Airflow direction cannot be set Ai...

Page 10: ...indows are open The air filter is clogged See Maintenance P 7 Too many heat sources in the room in cooling mode Use minimum heat sources and in a short time Too many people in the room in cooling mode...

Page 11: ...ZH2E8 PZ2 1 phase U 71PZ2E5 U 100PZ2E5 U 125PZ2E5 U 140PZ2E5 3 phase U 100PZ2E8 U 125PZ2E8 U 140PZ2E8 Outdoor unit type 36 50 60 PZH3 1 phase U 36PZH3E5 U 50PZH3E5 U 60PZH3E5 3 phase PZ3 1 phase U 36P...

Page 12: ...r input kW 0 035 0 040 0 040 0 050 0 055 0 080 0 110 0 120 Sound pressure level High dB A 36 37 37 38 39 42 46 47 Medium dB A 32 33 33 34 35 37 40 41 Low dB A 28 28 28 29 30 34 35 36 Sound power level...

Page 13: ...ing Heating dB A 65 67 69 69 70 70 71 71 Unit dimensions H W D mm 996 940 340 1 416 940 340 1 416 940 340 1 416 940 340 Net weight kg 68 99 99 99 Europe Model Name U 71PZH2E8 U 100PZH2E8 U 125PZH2E8 U...

Page 14: ...10 C 43 C DB Heating mode 15 C 24 C DB Europe Model Name U 100PZ2E8 U 125PZ2E8 U 140PZ2E8 Power source 380 400 415 V 3N 50 Hz Cooling capacity kW 10 0 12 5 14 0 BTU h 34 100 42 700 47 800 Heating capa...

Page 15: ...69 69 70 70 71 71 Unit dimensions H W D mm 996 940 340 1 416 940 340 1 416 940 340 1 416 940 340 Net weight kg 65 98 98 98 Europe Model Name U 71PZH3E8 U 100PZH3E8 U 125PZH3E8 U 140PZH3E8 Power sourc...

Page 16: ...0PZ3E8 U 125PZ3E8 U 140PZ3E8 Power source 220 230 240 V 50 Hz 380 400 415 V 3N 50 Hz Cooling capacity kW 10 0 12 5 14 0 10 0 12 5 14 0 BTU h 34 100 42 700 47 800 34 100 42 700 47 800 Heating capacity...

Page 17: ...ic com Panasonic Corporation 2020 2021 WEB ACXF55 28660 EN DC1020 10121 Authorised representative in EU Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg Germany 0...

Reviews: