background image

4

WARNING

Stop using the product when any 

abnormality/failure occurs and 

disconnect the power plug or turn 

off the power switch and breaker.

(Risk of smoke/fire/electric shock)

Examples of abnormality/failure:

• 

The ELCB trips frequently.

• 

The product sometimes does not 

start when turned on.

• 

The power is sometimes 

disconnected when the cord is 

moved.

• 

Burnt odor or abnormal noise is 

detected during operation.

• 

The body is deformed or 

abnormally hot.

• 

Water leaks from the indoor unit.

• 

Power cord or plug becomes 

abnormally hot.

• 

Fan speed cannot be controlled.

• 

The unit stops running 

immediately even if it is switched 

on for operation.

• 

The fan does not stop even if the 

operation is stopped.

Contact immediately your local 

dealer for maintenance/repair.

Do not sit or step on the unit.  

You may fall down accidentally.

This appliance is intended to be used by 

expert or trained users in shops, in light 

industry and on farms, or for commercial 

use by lay persons.
This appliance is not intended for use 

by persons (including children) with 

reduced physical, sensory or mental 

capabilities, or lack of experience 

and knowledge, unless they have 

been given supervision or instruction 

concerning use of the appliance by 

a person responsible for their safety.

Children should be supervised to ensure 

that they do not play with the appliance.
<for European market only>

This appliance can be used by 

children aged from 8 years and above 

and persons with reduced physical, 

sensory or mental capabilities or lack of 

experience and knowledge if they have 

been given supervision or instruction 

concerning use of the appliance in a 

safe way and understand the hazards 

involved. Children shall not play with 

the appliance. Cleaning and user 

maintenance shall not be made by 

children without supervision.

Keep the fire alarm and the air outlet at 

least 1.5 m away from the unit.
Do not cool or heat the room too much 

if babies or invalids are present.
Do not turn the air conditioner on and 

off from the power mains switch. Use 

the ON/OFF operation button.
Do not stick anything into the air 

outlet of the outdoor unit. This is 

dangerous because the fan is 

rotating at high speed.
Do not touch the air inlet or the 

sharp aluminum fins of the 

outdoor unit. You may get 

injured.
Do not stick any object  

into the FAN CASE. You 

may be injured and the unit 

may be damaged.

CAUTION

• The appliance shall be stored so as to prevent mechanical damage from occurring.

• 

The compressor may occasionally stop during thunderstorms. This is not a mechanical failure. The unit automatically recovers 

after a few minutes.

• 

The English text is the original instructions. Other languages are translation of the original instructions.

NOTICE

The appliance shall be stored 

in a room without continuously 

operating open flames (for 

example: an operating gas 

appliance) and ignition sources 

(for example: an operating electric 

heater).

01_330091_EN.indb   4

2021/1/13   9:49:04

Summary of Contents for T3 Series

Page 1: ...structions thoroughly and keep them for future reference Panasonic Corporation 1006 Kadoma Kadoma City Osaka Japan WEB ACXF55 28660 EN Ceiling Type T3 Model No INDOOR UNIT Ceiling Type T3 S 3650PT3E S...

Page 2: ...e as described in these Operating Instructions Confirm to authorized dealer or specialist on usage of specified refrigerant type Using of refrigerant other than the specified type may cause product da...

Page 3: ...oles must be incorporated in the fixed wiring in accordance with the wiring rules To prevent possible hazards from insulation failure the unit must be grounded WARNING Do not use modified cord joint c...

Page 4: ...appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision o...

Page 5: ...t recovery and recycling of old products and used batteries please take them to applicable collection points in accordance with your national legislation and the Directives 2002 96 EC and 2006 66 EC B...

Page 6: ...r intake Air intake Operation Adjusting Airflow Direction Refer to the Operating Instructions attached to the Remote Controller The flap display on the remote controller differs from the actual flap a...

Page 7: ...peration automatically Operation settings prior to power failure will be used WARNING z z For safety be sure to turn the air conditioner off and disconnect the power before cleaning Otherwise electric...

Page 8: ...opagations of mold and bacteria When purchased the nanoe X function is designed to automatically operate If you wish to set to OFF refer to the operating instructions for the remote controller adaptab...

Page 9: ...Fan rotation makes operation smooth The fan may rotate to dry the heat exchanger depending on the setting Airflow direction Airflow direction changes while operating Airflow direction cannot be set Ai...

Page 10: ...indows are open The air filter is clogged See Maintenance P 7 Too many heat sources in the room in cooling mode Use minimum heat sources and in a short time Too many people in the room in cooling mode...

Page 11: ...ZH2E8 PZ2 1 phase U 71PZ2E5 U 100PZ2E5 U 125PZ2E5 U 140PZ2E5 3 phase U 100PZ2E8 U 125PZ2E8 U 140PZ2E8 Outdoor unit type 36 50 60 PZH3 1 phase U 36PZH3E5 U 50PZH3E5 U 60PZH3E5 3 phase PZ3 1 phase U 36P...

Page 12: ...r input kW 0 035 0 040 0 040 0 050 0 055 0 080 0 110 0 120 Sound pressure level High dB A 36 37 37 38 39 42 46 47 Medium dB A 32 33 33 34 35 37 40 41 Low dB A 28 28 28 29 30 34 35 36 Sound power level...

Page 13: ...ing Heating dB A 65 67 69 69 70 70 71 71 Unit dimensions H W D mm 996 940 340 1 416 940 340 1 416 940 340 1 416 940 340 Net weight kg 68 99 99 99 Europe Model Name U 71PZH2E8 U 100PZH2E8 U 125PZH2E8 U...

Page 14: ...10 C 43 C DB Heating mode 15 C 24 C DB Europe Model Name U 100PZ2E8 U 125PZ2E8 U 140PZ2E8 Power source 380 400 415 V 3N 50 Hz Cooling capacity kW 10 0 12 5 14 0 BTU h 34 100 42 700 47 800 Heating capa...

Page 15: ...69 69 70 70 71 71 Unit dimensions H W D mm 996 940 340 1 416 940 340 1 416 940 340 1 416 940 340 Net weight kg 65 98 98 98 Europe Model Name U 71PZH3E8 U 100PZH3E8 U 125PZH3E8 U 140PZH3E8 Power sourc...

Page 16: ...0PZ3E8 U 125PZ3E8 U 140PZ3E8 Power source 220 230 240 V 50 Hz 380 400 415 V 3N 50 Hz Cooling capacity kW 10 0 12 5 14 0 10 0 12 5 14 0 BTU h 34 100 42 700 47 800 34 100 42 700 47 800 Heating capacity...

Page 17: ...ic com Panasonic Corporation 2020 2021 WEB ACXF55 28660 EN DC1020 10121 Authorised representative in EU Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg Germany 0...