27
SPOT EVENT
DWELL TIME
Set the dwell time for the display of the event activated channel.
(3-10sec)
SEQUENCE
Enable/disable sequential display of spot channel in full screen.
If select ON, spot channel selection screen is displayed.
SEQ-DWEL TIME
Set the dwell time for the spot channel display.(3-10sec)
SPOT CHANNEL
Select a channel for spot monitoring using the mouse or the control
button (
◀ ▲ ▶ ▼
) on the remote control and press OK button.
3-4-3 Controller & PTZ Setup
To control the PTZ functions of the camera, connect a controller to the RS-485 port.
①
Connect the RS-485 cables of PTZ camera to the RS-485 port on the rear panel.
②
Press the Controller & PTZ menu button. Then PTZ menu screen is displayed.
Figure 3.4.4. Controller & PTZ Setup Screen
Note
: For speed dome cameras that support RS-485, connect them directly to the RS-485 port. If the
camera is controlled with RS-232C, use an RS-485 to RS-232C signal converter.
On the PTZ control setup screen, you can select or set the protocol type of the camera that is the same as
the one installed on the site. If the camera has a specific camera ID, select the camera ID using the mouse
or the control button (
◀ ▲ ▶ ▼
) of the remote control.
The following options are available on the PTZ setup screen.
CONTROLLER
(controller type)
CHANNEL
(channel number that the PTZ is connected to)
NAME
(protocol type)
SPEED
(19200, 14400, 9600, 4800, 2400)
ID
(0-63)