Wiring
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
58
The auxiliary output is used to invalid the external device monitor function. The auxiliary output
should be set to “control output negative logic” (factory setting). External devices cannot be con-
nected to the auxiliary output.
●
Using line synchronization setting and 8-core cable
<Using PNP output>
Emitter
Receiver
K1
K2
+
24V DC
+20
-30
%
−
Gray cable
Gray cable
(with black line)
(Brown) +V
(Brown) +V
(Pale purple) Interlock setting input
(Pink) Test / Reset input
(Red) Auxiliary output
(Pale blue) Output polarity setting / Lockout release input
(Pale blue) Output polarity setting / Lockout release input
(Blue) 0V
(Blue) 0V
(Orange) Synchroni
(Pale purple) External device monitor input
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Orange) Synchroni
(Orange / Black) Synchronization -
(Orange / Black) Synchronization -
Interlock function
Invalid (auto reset)
External device monitor function Invalid
Auxiliary output
Cannot be used
*Symbols
K1, K2: Safety relay unit, etc.