Common specifications
Notes: 1) The operating ambient temperature is +20°C unless otherwise specified.
2) When
SF2B-H
□
and
SF2B-A
□
are combined in series connection, double the number of the beam channels
of
SF2B-A
□
to calculate the total number of beam channels, which should be 128 or less.
<e.g>: The total number of beam channels for
SF2B-H36
and
SF2B-A44SL
is 124.
The number of beam channels of
SF2B-H36
+
(the number of beam channels of
SF2B-A44SL
x 2)
= Total number of beam channels
36 beam ch (44 beam channels x 2) =124 beam channels
3) The intermediate supporting bracket (
MS-SF2B-2
) is enclosed with the following devices. The quantity of
the enclosed bracket differs depending on the device as follows:
1 set :
SF2B-H
□SL
…40 to 56 beam channels,
SF2B-A
□SL
…20 to 28 beam channels
2 sets :
SF2B-H
□SL
…64 to 80 beam channels,
SF2B-A
□SL
…32 to 40 beam channels
3 sets :
SF2B-H
□SL
…88 to 96 beam channels,
SF2B-A
□SL
…44 to 48 beam channels
<Reference>
Both emitter and receiver are adjusted before shipment, please apply both emitter and receiver with
the same serial No. The serial No. is indicated on the plates of both emitter and receiver. (Indicated
on the lower level of the model No.)