background image

© Panasonic Industrial Devices SUNX Co., Ltd. 2016 

 

- 5 -

 

Chapter 1  Introduction 

1-1  Attention Marks 

This instruction manual employs the following attention marks 

  depending 

on the degree of the danger to call operator’s attention to each particular action. Read the 
following explanation of these marks thoroughly and observe these notices without fail. 

 

If you ignore the advice with this mark, death or serious injury could result. 

 

If you ignore the advice with this mark, injury or material damage could 
result. 

<Reference> 

It gives useful information for better use of this device. 

 

1-2  Safety Precautions 

  Use this device as per its specifications. Do not modify this device since its functions and 

capabilities may not be maintained and it may malfunction.   

  This device has been developed / produced for industrial use only. 

  This device is suitable for indoor use only. 

  Use of this device under the following  conditions or environment is not presupposed. 

Please consult us if there is no other choice but to use this device in such an 
environment.   
1)  Operating this device under conditions or environments not described in this manual. 
2)  Using this device in the following fields: nuclear power control, railroad, aircraft, 

automobiles, combustion facilities, medical systems, aerospace development, etc. 

  When this device is to be used for enforcing protection of a person from any danger 

occurring around an operating machine, the user should satisfy the regulations 
established by national or regional security committees (Occupational Safety and Health 
Administration: OSHA, the European Standardization Committee, etc.). Contact the 
relative organization(s) for details. 

  In case of installing this device to a particular machine, follow the safety regulations in 

regard to appropriate usage, mounting (installation), operation and maintenance. The 
users including the installation operator are responsible for the introduction of this device.   

  Use this device by installing suitable protection equipment as a countermeasure for 

failure, damage, or malfunction of this device. 

  Before using this device, check whether the device performs properly with the functions 

and capabilities as per the design specifications. 

  In case of disposal, dispose this device as an industrial waste. 

 

 

 

Machine designer, installer, employer and operator 

  The machine designer, installer, employer and operator  are solely responsible to 

ensure that all applicable legal requirements relating to the installation and the use in 
any application are satisfied and all instructions for installation and maintenance 
contained in the instruction manual are followed. 

 

Whether this device functions as intended to and systems including this device comply 
with safety regulations depends on the appropriateness of the application, installation, 
maintenance and operation. The machine designer, installer, employer and operator 
are solely responsible for these items.

 

 

Engineer 

  The engineer would be a person who is appropriately educated, has widespread 

knowledge and experience, and can solve various problems which may arise during 
work, such as a machine designer, or a person in charge of installation or operation etc. 

 

Summary of Contents for SF2B Series

Page 1: ...Light Curtain SF2B Series Sub Sensor Exclusive for Series Connection SF2B SL Instruction Manual MJE SF2BSL No 0053 18V 2016 1 panasonic net id pidsx global...

Page 2: ...Panasonic Industrial Devices SUNX Co Ltd 2016 2 MEMO...

Page 3: ...light curtains as well as safety systems and standards who are responsible for the introduction of this device who design the system using this device who install and connect this device who manage a...

Page 4: ...Part Description 9 2 2 Mounting 11 2 2 1 Mounting of the Mounting Bracket 11 2 2 2 Mounting of the Connector for Series Connection Optional 15 2 3 Wiring 17 2 4 Adjustment 19 Chapter 3 Specifications...

Page 5: ...regional security committees Occupational Safety and Health Administration OSHA the European Standardization Committee etc Contact the relative organization s for details In case of installing this d...

Page 6: ...ng part of this device is directly exposed to light from high frequency fluorescent lamp inverter type or rapid starter fluorescent lamp Installation Always keep the correctly calculated safety distan...

Page 7: ...nowledge After maintenance or adjustment and before starting operation test this device following the set procedure For details refer to Instruction Manual for SF2B Series Clean this device with a cle...

Page 8: ...ng the bottom cap cable SF2B CB05 A optional this device does not conform to OSHA Reference The conformity to JIS OSHA and ANSI for this device has been evaluated by ourselves The CULUS Listing Mark i...

Page 9: ...m channels are blocked light Besides the receiver displays its status on the display section Beam channel The light emitting elements of the emitter and the light receiving elements of the receiver ar...

Page 10: ...e control output OSSD 1 2 the operation indicator is marked as OSSD on the device 2 The threshold where the control output OSSD 1 2 changes from OFF to ON is applied as 100 incident beam intensity 3 T...

Page 11: ...1 optional is used Configuration The standard mounting bracket MS SF2B 1 optional configures as follows 1 Fix the standard mounting bracket with two hexagon socket head bolts M3 length 5mm The tighte...

Page 12: ...e mounting bracket on to the mounting surface with two hexagon socket head bolts M5 please arrange separately temporarily 5 Adjust the height of the emitter and the receiver to level with the elongate...

Page 13: ...follows 1 Hook the C part into the groove on the side of the body and press it Note that the position to fit the C part onto the main body differs from the surface where the intermediate mounting bra...

Page 14: ...Devices SUNX Co Ltd 2016 14 2 Insert the D part or E part into the C part in the step 1 condition 3 Mount the D part or E part on to the mounting surface with the two hexagon socket head bolts M5 plea...

Page 15: ...SF2B CSL into the connector of the main sensor SF2B and the sub sensor this device When inserting the connector fit the cable into the groove of the main sensor SF2B and the sub sensor this device 3...

Page 16: ...ection 1 For dismantling the cable for series connection follow the above procedure of Constructing method for the series connection in reverse The cable for series connection SF2B CSL cannot be exten...

Page 17: ...od depends on the type of bottom cap cable Refer to Instruction Manual for SF2B Series for the details of wiring When SF2B H and SF2B A are combined in series connection double the number of the beam...

Page 18: ...incorporated in the main sensor such as SF2B H8 or SF2B A4 it cannot be connected in series The connector for series connection is not incorporated in the sub sensors such as SF2B H8SL or SF2B A4SL In...

Page 19: ...in light blocked status the control output OSSD 1 2 turns OFF Reference The emitter receiver indicators indicate the output status The following figure shows the status of the indicators with Sub Sens...

Page 20: ...Panasonic Industrial Devices SUNX Co Ltd 2016 20 Beam synchronization using 4 core cable When sufficient light is received...

Page 21: ...vices SUNX Co Ltd 2016 21 Chapter 3 Specifications Dimensions 3 1 Specifications Model Example SF2B H56SL Beam pitch 20mm Number of beam channels 56 channels Model wise specifications Min sensing obje...

Page 22: ...Panasonic Industrial Devices SUNX Co Ltd 2016 22 Min sensing object 47mm 40mm pitch type...

Page 23: ...r of beam channels 36 beam channels 44 beam channels x 2 124 beam channels 3 The intermediate supporting bracket MS SF2B 2 is enclosed with the following devices The quantity of the enclosed bracket d...

Page 24: ...Panasonic Industrial Devices SUNX Co Ltd 2016 24 3 2 Dimensions 3 2 1 Rear Mounting with Standard Mounting Bracket MS SF2B 1...

Page 25: ...Panasonic Industrial Devices SUNX Co Ltd 2016 25 3 2 2 Side Mounting with Standard Mounting Bracket MS SF2B 1...

Page 26: ...ng Center EU Representative s Address Winsbergring 15 22525 Hamburg Germany Product Active Opto electronic Protective Device Light Curtain Model Name SF2B Series Trade Name Panasonic Application of Co...

Page 27: ...irst edition June 30 2006 Second edition August 31 2007 Third edition October 20 2008 Forth edition October 1 2009 Fifth edition December 20 2010 Sixth edition January 30 2012 Seventh edition January...

Page 28: ...Panasonic Industrial Devices SUNX Co Ltd 2016 28 MEMO...

Page 29: ...R ANY INDIRECT INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES OF ANY KIND GENERAL TERMS AND CONDITIONS 4 OR ANY DAMAGES RESULTING FROM LOSS OF USE BUSINESS INTERRUPTION LOSS OF INFORMATION LOSS OR INACCU...

Page 30: ...ama cho Kasugai shi Aichi 486 0901 Japan Telephone 81 568 33 7861 Facsimile 81 568 33 8591 panasonic net id pidsx global For sales network please visit our website Panasonic Industrial Devices SUNX Co...