background image

  © Panasonic Industrial Devices SUNX Co., Ltd. 2016 

- 6 - 

 

 

Operator 

  The operator should read this instruction manual thoroughly, understand its contents, 

and perform operations following the procedures described in this manual for the 
correct operation of this device. 

  In case this device does not perform properly, the operator  should report this to the 

person in charge and stop the machine operation immediately. The machine must not 
be operated until correct performance of this device has been confirmed. 

 

Environment 

  Do not use a mobile phone or a radio phone near this device. 

  If there exists a reflective surface in the place where this device is to be installed, make 

sure to install this device so that reflected light from the reflective surface does not 
enter into the receiver, or take countermeasures such as painting, masking, 
roughening, or changing the material of the reflective surface, etc. Failure to do so may 
cause the device not to detect, resulting in death or serious injury. 

  Do not install this device in the following environments. 

1)  Areas exposed to intense interference (extraneous) light such as direct sunlight 
2)  Areas with high humidity where condensation is likely to occur 
3)  Areas exposed to corrosive or explosive gases 
4)  Areas exposed to vibration or shock of levels higher than that specified 
5)  Areas exposed to contact with water 
6)  Areas exposed to too much steam or dust 
7)  Areas where the light-receiving part of this device is directly exposed to light from 

high-frequency fluorescent lamp (inverter type) or rapid starter fluorescent lamp.   

 

Installation 

  Always keep the correctly calculated safety distance between this device and the 

dangerous parts of the machine. 

  Install extra protection structure around  the machine so that the operator must pass 

through the sensing area of this device to reach the dangerous parts of the machine.   

  Install this device such that some part of the operator’s body always remains in the 

sensing area when operator is done with the dangerous parts of the machine. 

  Do not install this device at a location where it can be affected by wall reflection. 

  When installing multiple sets of this device, connect the sets and, if necessary, install 

some barriers such that mutual interference does not occur. 

  Do not use this device in a reflective configuration. 

 

Machine in which this device is installed 

  Do not use this device as a safety equipment for a press machine. 

  Do not install this device with  a machine whose operation cannot be stopped 

immediately in the middle of an operation cycle by an emergency stop equipment. 

  This device starts the performance after 2 seconds from the power ON. Have the 

control system started to function with this timing. 

 

Wiring 

  Be sure to carry out the wiring in the power supply OFF condition. 

  Do not use this device during the initial transient time (approx. 2 sec.) after the power 

supply is switched ON. 

  All electrical wiring should conform to the regional electrical regulations and laws.  

The wiring should be done by engineer(s) having the special electrical knowledge. 

 

Summary of Contents for SF2B Series

Page 1: ...Light Curtain SF2B Series Sub Sensor Exclusive for Series Connection SF2B SL Instruction Manual MJE SF2BSL No 0053 18V 2016 1 panasonic net id pidsx global...

Page 2: ...Panasonic Industrial Devices SUNX Co Ltd 2016 2 MEMO...

Page 3: ...light curtains as well as safety systems and standards who are responsible for the introduction of this device who design the system using this device who install and connect this device who manage a...

Page 4: ...Part Description 9 2 2 Mounting 11 2 2 1 Mounting of the Mounting Bracket 11 2 2 2 Mounting of the Connector for Series Connection Optional 15 2 3 Wiring 17 2 4 Adjustment 19 Chapter 3 Specifications...

Page 5: ...regional security committees Occupational Safety and Health Administration OSHA the European Standardization Committee etc Contact the relative organization s for details In case of installing this d...

Page 6: ...ng part of this device is directly exposed to light from high frequency fluorescent lamp inverter type or rapid starter fluorescent lamp Installation Always keep the correctly calculated safety distan...

Page 7: ...nowledge After maintenance or adjustment and before starting operation test this device following the set procedure For details refer to Instruction Manual for SF2B Series Clean this device with a cle...

Page 8: ...ng the bottom cap cable SF2B CB05 A optional this device does not conform to OSHA Reference The conformity to JIS OSHA and ANSI for this device has been evaluated by ourselves The CULUS Listing Mark i...

Page 9: ...m channels are blocked light Besides the receiver displays its status on the display section Beam channel The light emitting elements of the emitter and the light receiving elements of the receiver ar...

Page 10: ...e control output OSSD 1 2 the operation indicator is marked as OSSD on the device 2 The threshold where the control output OSSD 1 2 changes from OFF to ON is applied as 100 incident beam intensity 3 T...

Page 11: ...1 optional is used Configuration The standard mounting bracket MS SF2B 1 optional configures as follows 1 Fix the standard mounting bracket with two hexagon socket head bolts M3 length 5mm The tighte...

Page 12: ...e mounting bracket on to the mounting surface with two hexagon socket head bolts M5 please arrange separately temporarily 5 Adjust the height of the emitter and the receiver to level with the elongate...

Page 13: ...follows 1 Hook the C part into the groove on the side of the body and press it Note that the position to fit the C part onto the main body differs from the surface where the intermediate mounting bra...

Page 14: ...Devices SUNX Co Ltd 2016 14 2 Insert the D part or E part into the C part in the step 1 condition 3 Mount the D part or E part on to the mounting surface with the two hexagon socket head bolts M5 plea...

Page 15: ...SF2B CSL into the connector of the main sensor SF2B and the sub sensor this device When inserting the connector fit the cable into the groove of the main sensor SF2B and the sub sensor this device 3...

Page 16: ...ection 1 For dismantling the cable for series connection follow the above procedure of Constructing method for the series connection in reverse The cable for series connection SF2B CSL cannot be exten...

Page 17: ...od depends on the type of bottom cap cable Refer to Instruction Manual for SF2B Series for the details of wiring When SF2B H and SF2B A are combined in series connection double the number of the beam...

Page 18: ...incorporated in the main sensor such as SF2B H8 or SF2B A4 it cannot be connected in series The connector for series connection is not incorporated in the sub sensors such as SF2B H8SL or SF2B A4SL In...

Page 19: ...in light blocked status the control output OSSD 1 2 turns OFF Reference The emitter receiver indicators indicate the output status The following figure shows the status of the indicators with Sub Sens...

Page 20: ...Panasonic Industrial Devices SUNX Co Ltd 2016 20 Beam synchronization using 4 core cable When sufficient light is received...

Page 21: ...vices SUNX Co Ltd 2016 21 Chapter 3 Specifications Dimensions 3 1 Specifications Model Example SF2B H56SL Beam pitch 20mm Number of beam channels 56 channels Model wise specifications Min sensing obje...

Page 22: ...Panasonic Industrial Devices SUNX Co Ltd 2016 22 Min sensing object 47mm 40mm pitch type...

Page 23: ...r of beam channels 36 beam channels 44 beam channels x 2 124 beam channels 3 The intermediate supporting bracket MS SF2B 2 is enclosed with the following devices The quantity of the enclosed bracket d...

Page 24: ...Panasonic Industrial Devices SUNX Co Ltd 2016 24 3 2 Dimensions 3 2 1 Rear Mounting with Standard Mounting Bracket MS SF2B 1...

Page 25: ...Panasonic Industrial Devices SUNX Co Ltd 2016 25 3 2 2 Side Mounting with Standard Mounting Bracket MS SF2B 1...

Page 26: ...ng Center EU Representative s Address Winsbergring 15 22525 Hamburg Germany Product Active Opto electronic Protective Device Light Curtain Model Name SF2B Series Trade Name Panasonic Application of Co...

Page 27: ...irst edition June 30 2006 Second edition August 31 2007 Third edition October 20 2008 Forth edition October 1 2009 Fifth edition December 20 2010 Sixth edition January 30 2012 Seventh edition January...

Page 28: ...Panasonic Industrial Devices SUNX Co Ltd 2016 28 MEMO...

Page 29: ...R ANY INDIRECT INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES OF ANY KIND GENERAL TERMS AND CONDITIONS 4 OR ANY DAMAGES RESULTING FROM LOSS OF USE BUSINESS INTERRUPTION LOSS OF INFORMATION LOSS OR INACCU...

Page 30: ...ama cho Kasugai shi Aichi 486 0901 Japan Telephone 81 568 33 7861 Facsimile 81 568 33 8591 panasonic net id pidsx global For sales network please visit our website Panasonic Industrial Devices SUNX Co...

Reviews: