© Panasonic Industrial Devices SUNX Co., Ltd. 2016
50
Chapter 4 Setting of Logics
4-1 Types and Settings of Logics
For this device, logic Nos. 0 to 9 and nine types of OFF delay time can be specified.
With logic No. 0 specified, the logic is customizable. This device must be connected to a PC to
make settings with a software tool.
Logics corresponding to Nos. are shown in the table below.
No.
Logic
0
Customizable logic
1
Overall stop control
2
Parallel muting control
3
Sequential muting control
4
Partial stop control 1
5
Partial stop control 2
6
Two-hand control
7
OR control
8
Operation mode selection control
OFF delay times and stop categories corresponding to Nos. are shown in the table below.
No.
OFF delay time
Stop category
0
0 sec.
0
1
0.1 sec.
1
2
0.5 sec.
3
1 sec.
4
2 sec.
5
5 sec.
6
10 sec.
7
15 sec.
8
30 sec.
9
60 sec.
4-1-1 Factory Setting
Factory setting of this device is as shown in the table below.
Item
Factory setting
Logic
OFF delay time No.
Password 1
Password 2