Functions
[No.3. Sequential muting control]
Logic diagram
IN1
IN3
IN5
IN7
IN2
IN4
IN6
IN8
OUT1
OUT3
OUT2
OUT4
Muting input
(equivalence)
PNP semicon-
ductor input × 2
(equivalence)
Muting input
(equivalence)
Override input
S-MUTE
Description of settings
Input
IN1 / IN2
PNP semiconductor input × 2
(equivalence)
IN5 / IN6
Muting input (equivalence)
IN3 / IN4
Muting input (equivalence)
IN7 / IN8
Override input
Control
output
OUT1 / 2
Interlock
Overall reset
OFF delay
0 sec. (Note 1)
OUT3 / 4
Interlock
Overall reset
OFF delay
0 sec. (Note 2)
Auxiliary
output
AUX1
Negative logic of OUT 1 / 2
AUX3
Reset trigger
AUX2
Negative logic of OUT 3 / 4
AUX4
Lockout
Notes: 1) Fixed at 0 sec.
2) Time can be selected using this device. For details, refer to “
<Timing chart>
●
When auto reset is set
IN1
IN3
IN5
IN7
IN2
IN4
IN6
IN8
T1
T3
T5
T7
T2
T4
T6
T8
OUT1/2
OUT3/4
Closed
Closed
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
Open
Open
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
MUTE
OVERRIDE
100ms or less
100ms or less
0.05 sec. or less
0.05 sec. or less
Allowable tolerance of
0.03 to 288,000 sec.
Allowable tolerance of 0.03 to 288,000 sec.
10ms or less
10ms or less
Intrusion of obstacles
Removal of obstacles
10ms or less
10ms or less
3 sec. + 0.05 sec. or less
Muting status
Muting status
Override status
1 sec. or less