Auxiliary Output Block
5-14 Auxiliary Output Block
Operations of four auxiliary outputs of this device
are set.
Click and select the auxiliary output block.
“Muting indicator output: MUTE” cannot be changed.
Initial settings are as follows:
AUX1
negative logic output of OUT1 / OUT2
AUX2
Negative logic of OUT3 / OUT4
AUX3
Reset trigger output
AUX4
Lockout output
MUTE
Muting indicator output (fixed)
The following operations can be set in auxiliary out-
puts.
●
Positive logic output or negative logic output of
OUT1 / OUT2
●
Positive logic output or negative logic output of
OUT3 / OUT4
●
Output A / B / C / D of diagnosis results of input
block 1 / 2 / 3 / 4
●
Output E / F / G of diagnosis results of internal
logical circuit
●
Reset trigger output
●
Lockout output
●
Muting indicator output
●
Monitor output of IN1 to 8
●
Normally off
Also refer to “
”.