background image

INSTRUCTION MANUAL

Application Expansion Unit Exclusive for Light Curtain

SF-C14EX

MJE-SFC14EX No.0053-44V

Thank you very much for purchasing Panasonic products.
Please read this Instruction Manual carefully and thoroughly for the cor-
rect and optimum use of this product. Kindly keep this manual in a con-
venient place for quick reference.
English and Japanese are original instructions.

SAFETY PRECAUTIONS

1

 

This product has been developed / produced for industrial use only.

 

● Use this product as per its specifications. Do not modify this product since 

its functions and capabilities may not be maintained and it may malfunction.

 

Use of this product under the following conditions or environments is 
not presupposed. Please consult us if there is no other choice but to 
use this product in such an environment.
1) Operating this product under conditions or environments not de-

scribed in this manual.

2) Using this product in the following fields: nuclear power control,

railroad, aircraft, automobiles, combustion facilities, medical sys

-

tems, aerospace development, etc.

 

When this product is to be used for enforcing protection of a person from 

any danger occurring around an operating machine, the user should satisfy 

the regulations established by national or regional security committees (Oc-

cupational Safety and Health Administration: OSHA, the European Stan

-

dardization Committee, etc.). Contact the relative organization(s) for details.

 

● In case of installing this product to a particular machine, follow the 

safety regulations in regard to appropriate usage, mounting (installa

-

tion), operation and maintenance. The users including the installation 

operator are responsible for the introduction of this product.

 

Use this product by installing suitable protection equipment as a 

countermeasure for failure, damage, or malfunction of this product.

 

● Before using this product, check whether the product performs proper

-

ly with the functions and capabilities as per the design specifications.

 

● In case of disposal, dispose this product as an industrial waste.

WARNING

 

Machine designer, installer, employer and operator

• The machine designer, installer, employer and operator are solely

responsible to ensure that all applicable legal requirements relat-

ing to the installation and the use in any application are satisfied.

Whether this product functions as intended and systems including this
product comply with safety regulations depends on the appropriateness

of the application, installation and operation. The machine designer,

installer, employer and operator are solely responsible for these items.

 

Engineer

• The engineer would be a person who is appropriately educated,

has widespread knowledge and experience, and can solve vari

-

ous problems which may arise during work, such as a machine

designer, or a person in charge of installation or operation, etc.

 

Operator

• The operator should read this instruction manual thoroughly, under

-

stand its contents, and perform operations following the procedures

described in this manual for the correct operation of this product.

• In case this product does not perform properly, the operator

should report this to the person in charge and stop machine op-
eration immediately. The machine must not be operated until cor-

rect performance of this product has been confirmed.

 

Environment

• Do not use a mobile phone or a radio phone near this product.

• Do not install this product in the following environments.

1) Areas with high humidity where condensation is likely to occur
2) Areas exposed to corrosive or explosive gases
3)

Areas exposed to vibration or shock of levels higher than that specified

4) Areas exposed to contact with water
5) Areas exposed to too much steam or dust

 

Machine in which this product is installed

Never use this product as a safety device for a press machine in Japan.

• Do not install this product with a machine whose operation can

-

not be stopped immediately in the middle of an operation cycle
by an emergency stop equipment.

This product starts the performance after 2 sec. from the power
ON. Have the control system started to function with this timing.

 

Wiring

Be sure to carry out the wiring in the power supply OFF condition.

• 

All electrical wiring should conform to the regional electrical regulations and laws.
The wiring should be done by engineer(s) having special electrical knowledge.

•  Do not run the wires together with high-voltage lines or power lines or put 

them in the same raceway. This can cause malfunction due to induction.

CAUTIONS

2

OUTLINE

3

 

This is the application expansion unit which can control three differ-
ent safety outputs in combination with the light curtain.

It exhibits the following features:

1) Either PNP or NPN output can be selected with the slide switch.
2) It can be connected to the light curtain using the exclusive 8-core

connection cable with connectors.

3) A detachable spring gauge terminal is employed.
4)

The three auxiliary outputs (muting output, override output and blown

lamp output) and the auxiliary output of the light curtain are incorporated.

5) The interference prevention wiring among the light curtains is pos-

sible. Maximumly three sets in series / parallel mixed connection can

be configured with the interference prevention system. The number of

total beam channels in series / parallel mixed connection is 192 max.

6) The product enables to set each function using the handy control-

ler 

SFB-HC

 (Ver. 2 or later) (optional). Refer to “

FUNCTIONS

USING HANDY CONTROLLER SFB-HC (OPTIONAL)

.”

 

This device complies with the following standards / regulations.

<EU Directives>

EU Machinery Directive 2006/42/EC

EMC Directive 2004/108/EC (Valid until April 19, 2016)

EMC Directive 2014/30/EU (Valid from April 20, 2016)

RoHS Directive 2011/65/EU

<European Standards>

EN 61496-1 (Type 4), EN 55011, EN ISO 13849-1: 2008 (Category 4, PLe)

<International Standards>

IEC 61496-1 (Type 4), ISO 13849-1: 2006 (Category 4, PLe)

<Japanese Industrial Standards (JIS)>

JIS B 9704-1 (Type 4), JIS B 9705-1 (Category 4)

<Standards in US / Canada)>

ANSI/UL 61496-1 (Type 4), ANSI/UL 508, UL 1998 (Class 2)

CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8

<Regulations in US>

OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06

Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has 

certified with the type examination certificate.

With regard to the standards in US / Canada, a NRTL, UL (Under

-

writers Laboratories Inc.) has certified for 

C

UL

US

 Listing Mark.

<Reference>

The conformity to JIS, OSHA and ANSI for this device has been evaluated by ourselves.

 

The light curtains that can be used in combination with this product are as follows.

SF4B

 / 

SF4B<V2>

 series and 

SF4B-□-01

 / 

SF4B-□-01<V2>

WARNING

 

Maintenance

The periodical inspection of this product must be performed by an
engineer having the special knowledge.

 

Others

Never modify this product.

 

When connecting this product to a product other than the connect-

able input device, the system does not conform to the control cat

-

egory 4 basd on ISO 13849-1 (EN ISO 13849-1). 

 

Connect this product to the same power supply which the light curtain uses.

 

Take care that wrong wiring will damage the product.

 

Verify that the supply voltage variation is within the rating. Take care 

that if a voltage exceeding the rated range is applied, or if an AC power 

supply is directly connected, the product may get burnt or damaged.

 

● The DC power supply unit must satisfy the conditions given below:

1) Power supply unit authorized in the region where this product is to be used.
2) Power supply unit SELV (safety extra low voltage) / PELV (pro-

tected extra low voltage) conforming to EMC Directive and Low-

voltage Directive (In case CE Marking conformity is required.)

3) Power supply unit conforming to the Low-voltage Directive and

with an output of 100VA or less.

4) The frame ground (F.G.) terminal must be connected to ground

when using a commercially available switching regulator.

5) Power supply unit with an output holding time of 20ms or more.

6) In case a surge is generated, take countermeasures such as con

-

necting a surge absorber to the origin of the surge.

7) Power supply unit corresponding to CLASS 2 (only for requiring

C

UL

US

 Mark conformation).

 

This product is not dust-proof / splash proof. Be sure to put this prod-
uct into a control box having IP54 construction.

 

● Avoid dust, dirt, and steam.

 

● Take care that the product does not come in contact with water, oil, 

grease, or organic solvents such as thinner, etc.

 

The seal as shown in the drawing on the right 
is stuck to the engagement point of unit. If 

the seal is peeled off or broken, this product 

will not be certified as a “Safety equipment” 

and will not be covered by our guarantee.

 

Note that this product is applicable only in the control circuit grounded in 

accordance with IEC 60204-1 and JIS B 9960-1, or in the control circuit in 

which the insulation monitor unit (ground fault detection unit) is arranged.

 

This product is suitable for indoor use only.

Do not open!

If this seal is removed or damaged,

 

the units are not recognized as safety product.

Panasonic Electric Works SUNX Co., Ltd.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Summary of Contents for SF-C14EX

Page 1: ... raceway This can cause malfunction due to induction CAUTIONS 2 OUTLINE 3 This is the application expansion unit which can control three differ ent safety outputs in combination with the light curtain It exhibits the following features 1 Either PNP or NPN output can be selected with the slide switch 2 It can be connected to the light curtain using the exclusive 8 core connection cable with connect...

Page 2: ...r cable length 10m SFB CCJ10D for receiver cable length 10m The following cables are recommended for power supply side con nector and other connector Power supply side connector A1 and A2 0 2 to 2 5mm2 AWG 24 to 12 Other connector 0 2 to 1 5mm2 AWG 24 to 16 Cable extension is possible up to 50m for each emitter receiver However 30m or less for each emitter receiver for two sets in series connectio...

Page 3: ...or 0V V OUT 0V V OUT 0V Muting sensor 1 PNP output type Muting sensor 2 NPN output type 1 1 Test input Override input Muting lamp output 1 3 6 to 30W Muting lamp output 2 3 6 to 30W 24V 3 Control circuit 24V DC Output polarity selection switch 2 Emergency stop switch 4 4 4 Wiring in auto reset setting broken line PLC etc TIMING CHART 10 Normal operation The diagram shows operation with safety outp...

Page 4: ...e output corresponding to the external emergency stop switch When the emergency stop is invalid ON When the emergency stop is valid OFF However if the emergency stop is valid both safety outputs 1 2 are OFF Note When the safety output is ON the output transistor goes OFF periodically to self diagnose the output circuit OFF pulse width 100μs or less When the OFF signal is fedback it is judged that ...

Page 5: ... display red When the muting function and the fixed blanking function the float ing blanking function are set the fixed blanking function the float ing blanking function are prioritized Fixed blanking function This function enables to protect the control output OSSD 1 2 from turning into OFF even though the specific beam channel is blocked The factory setting is set to be invalid for the fixed bla...

Page 6: ...esistance 3Ω or less Operation mode Output operation Safety output 1 When light curtain is in light received status ON When light curtain is in light blocked status OFF Note 2 Safety output 2 When light curtain is in light received status or the muting function is valid ON When light curtain is in light blocked status and the mut ing function is invalid OFF Note 2 Safety output 3 When the emergenc...

Page 7: ...inks The handy controller SFB HC has been connected Remove the handy controller SFB HC Only the power indicator green and the auxiliary output 1 2 and 3 indica tors orange light up All of the safety outputs 1 2 and 3 are OFF The product is in emergency stop state Wire the emergency stop input output terminals between S11 and S12 and S21 and S22 correctly Check if the emergency stop switch has been...

Reviews: