21
5.3.
Main body test mode
5.3.1.
Setting the main body initial test mode
Operation procedure
1. Insert the power cord plug into an electrical outlet.
2. Press the "Menu" "Crust"
and "Start" keys at the same time.
Phenomena
• LCD indication: All indications displayed
• Behaviour of device: Load other than LCD is off.
• Restoration: Pressing "Stop" key, the device returns to the
normal initial mode.
* When all indications do not appear on the LCD, check the
device again following the above operations.
Judgement/Remedy
• When all the indications do not appear on the LCD, replace
P.C.Boards A and/or B.
Check the device condition in this test mode after replacing
the P.C.Board (s).
All Light up
Chidori Light up
Summary of Contents for SD-ZB2502BXC
Page 2: ...2 1 Safety Precautions ...
Page 4: ...4 3 Location of Controls and Components ...
Page 5: ...5 ...
Page 6: ...6 4 Operating Instructions 4 1 Befor Use ...
Page 7: ...7 4 2 How to Use ...
Page 8: ...8 ...
Page 9: ...9 ...
Page 10: ...10 ...
Page 11: ...11 ...
Page 12: ...12 ...
Page 13: ...13 4 3 How to Clearn ...
Page 14: ...14 4 4 Trouble shooting ...
Page 15: ...15 ...
Page 20: ...20 4 Buzzer interlocking movement rumbling mode during a main body test Start key Menu key ...
Page 29: ...29 7 Remove the screw and nut then detach the Ground wire A 8 Remove the body ...
Page 39: ...39 6 12 Sensor 1 Remove screw nut off the heater case unit and change a sensor assy ...
Page 42: ...42 7 Wiring Connection Diagram 7 1 Schematic diagram ...
Page 43: ...43 7 2 Basic wiring diagram ...
Page 44: ...44 8 Exploded View and Replacement Parts List 8 1 PARTS LOCATION ...
Page 47: ...47 8 3 PACKING INSTRUCTION ...